PCV-VG Versus VCV Through the I-gel in Young Children

Trial statusNot yet recruiting
Trial phaseNot applicable
Trial typeInterventional
Biological sexAll
Age2-7
SponsorBeni-Suef University

About this trial

Supraglottic airway devices (SADs) like the i-gel are frequently used to manage airways during general anesthesia in children. However, delivering positive-pressure mechanical ventilation through a supraglottic airway carries a risk of gas leaking around the cuff into the stomach (gastric insufflation), which can cause stomach distension and increase the risk of regurgitation.

Volume-controlled ventilation (VCV) delivers a fixed breath volume, which can cause spikes in peak inspiratory pressure if airway resistance changes, potentially exceeding the device seal and forcing air into the stomach. Pressure-controlled ventilation with volume guarantee (PCV-VG) uses closed-loop feedback to auto-titrate inspiratory pressure breath-by-breath to target the desired tidal volume while minimizing peak airway pressures.

This prospective, single-center, randomized controlled trial aims to evaluate whether PCV-VG offers superior ventilatory efficacy (accurate tidal volume delivery) and enhanced gastric safety (lower incidence of ultrasonographically detected gastric insufflation) compared to VCV when using the i-gel supraglottic airway in children aged 2 to 7 years undergoing elective non-laparoscopic surgery

Eligibility criteria

This trial does not accept healthy volunteers

Qualifiers

Children aged 2 to 7 years inclusive

Body weight 10 to 25 kg inclusive

American Society of Anesthesiologists (ASA) physical status classification I or II

Scheduled for elective non-laparoscopic surgical procedures of anticipated duration 30 to 120 minutes, not involving the airway, head, or neck (e.g., orthopedic, urological, perineal, or minor extremity procedures)

Disqualifiers

Anticipated or known difficult airway (history of failed supraglottic airway device insertion, syndromic anatomical airway anomalies, Mallampati class IV, or inter-incisor gap < 20 mm)

Active upper or lower respiratory tract infection within 2 weeks prior to surgery

Reactive airway disease (asthma or bronchiolitis) with active wheeze or exacerbation within 4 weeks

Obesity: body mass index (BMI) ≥ 97th centile for age and sex according to WHO Child Growth Standards (2006)

Trial design

Design model

Parallel

Treatments tested in this trial

  • Pressure-Controlled Ventilation with Volume Guarantee (PCV-VG)

    Procedure/Surgery

    Administration of closed-loop pressure-controlled ventilation with volume guarantee via the i-gel supraglottic airway, maintaining target VT 6-7 mL/kg IBW with breath-by-breath inspiratory pressure auto-titration.

  • Volume-Controlled Ventilation (VCV)

    Procedure/Surgery

    Administration of traditional volume-controlled ventilation with constant inspiratory flow via the i-gel supraglottic airway, maintaining set VT 6-7 mL/kg IBW without automated pressure adaptation.

Treatment groups

90 Participants
are divided into 2 treatment groups
Group A: Group PCV-VG (Pressure-Controlled Ventilation with Volume Guarantee)Experimental treatment 1 intervention
Group B: Group VCV (Volume-Controlled Ventilation)Active comparator 1 intervention

Trial outcomes

Primary outcomes

1

Mean Expired Tidal Volume (VTe) Delivery Accuracy

Measured in milliliters per kilogram of ideal body weight (mL/kg IBW) using the anesthesia workstation flow sensor. Evaluates delivery accuracy relative to the prescribed target (6.0-7.0 mL/kg IBW). Values within the target prescribed range (6.0-7.0 mL/kg IBW) indicate a good result (effective alveolar ventilation). Values significantly below target (\< 5.0 mL/kg IBW) indicate a bad result (hypoventilation due to circuit leak), while values above target (\> 8.0 mL/kg IBW) indicate a bad result (risk of volutrauma).

Time frame
Measured at 20 minutes post-initiation of mechanical ventilation (T1) and at end of surgery / pre-emergence (T2, up to 120 minutes)
2

Percentage of Participants With Ultrasonographically Confirmed Gastric Insufflation

Defined as an increase in serial radiologist-measured gastric antrum cross-sectional area (CSA) ≥ 20% from baseline (T0), confirmed on ≥ 2 of 3 measurements at either T1 or T2, calculated using the ellipse formula: CSA=(π × D1 × D2)/4 A lower percentage indicates a good result (enhanced gastric safety and effective airway seal). A higher percentage indicates a bad result (increased risk of gastric distension, elevated intra-abdominal pressure, and pulmonary aspiration).

Time frame
Intraoperative period (assessed at 20 minutes post-ventilation [T1] and end of surgery [T2], up to 120 minutes total)

Secondary outcomes

1

Mean Peak Inspiratory Pressure (Ppeak)

Peak airway pressure measured in centimeters of water (cmH2O) directly from the anesthesia workstation pressure transducer. A lower value indicates a good result (reduced risk of barotrauma and lower potential to exceed oropharyngeal leak pressure). A higher value indicates a bad result (increased pulmonary barotrauma risk and higher likelihood of driving gas into the esophagus).

Time frame
Measured at 20 minutes post-initiation of mechanical ventilation (T1) and at end of surgery / pre-emergence (T2, up to 120 minutes)
2

Mean Dynamic Respiratory System Compliance (Cdyn)

Calculated using the formula: Cdyn= (VTe) ÷(Ppeak-PEEP), expressed in mL/cmH2O. A higher value indicates a good result (superior lung/thoracic compliance and lower resistance to inflation). A lower value indicates a bad result (stiffer lungs, higher airway resistance, or increased impedance).

Time frame
Measured at 20 minutes post-initiation of mechanical ventilation (T1) and at end of surgery / pre-emergence (T2, up to 120 minutes)
3

Mean Oropharyngeal Leak Pressure (OLP)

Airway pressure in cmH2O at which an anterior cervical leak is detected on precordial auscultation during circuit occlusion. A higher value indicates a good result (a tighter perilaryngeal device seal capable of sustaining higher positive pressure without leaking). A lower value indicates a bad result (poor device seal and higher risk of leak).

Time frame
Measured immediately post-i-gel placement (T0) and at 20 minutes post-initiation of mechanical ventilation (T1)
4

Mean End-Tidal Carbon Dioxide (EtCO2) Concentration

Measured in millimeters of mercury (mmHg) using continuous side-stream capnography on the anesthesia workstation to assess systemic ventilation status and carbon dioxide elimination. Directional Interpretation: Values within the physiological target range (35-45 mmHg) indicate a good result (optimal normocapnic ventilation). Values significantly above target (\> 45 mmHg) indicate a bad result (hypercapnia/hypoventilation due to circuit leak or dead-space rebreathing), while values below target (\< 30 mmHg) indicate a bad result (hypocapnia due to hyperventilation).

Time frame
Measured at T0 (post-i-gel placement), T1 (20 minutes post-ventilation start), T2 (end of surgery), and at emergence / i-gel removal (up to 120 minutes)

Other outcomes