About this trial
This study is being done to evaluate the clinical utilization and safety of RayStation 2025 and RayCare 2025 treatment planning software upgrades when used to support standard-of-care proton therapy delivery in patients deemed clinically appropriate for such therapy by their treating radiation oncologist.
Eligibility criteria
This trial does not accept healthy volunteersQualifiers
Age less than or equal to 17 years at the time of consent/assent.
Patient has a clinical indication for radiation therapy, and the treating radiation oncologist has independently determined that proton therapy is clinically appropriate and has recommended proton therapy as part of the patient's routine clinical care, independent of participation in this research study. Proton therapy may be delivered with or without anesthesia when clinically indicated.
Written informed consent will be obtained from adult subjects or the parent/legal guardian of pediatric subjects. Assent will be obtained from pediatric participants when appropriate according to institutional policy.
Disqualifiers
Patient has contraindications to proton therapy (per standard clinical guidelines).
Patient is unable to comply with routine treatment workflow or follow-up.
Patients who will be treated with a radiation plan of 5 fractions or fewer.
Trial design
Single group
Treatments tested in this trial
RayTracker and RayAdaptive Software Analysis
DevicePart of a not yet FDA-cleared software, the RaySearch treatment planning system and RayCare oncology information system. RayTracker enables longitudinal evaluation of treatment by recalculating dose on daily images and accumulating dose across fractions using deformable image registration, thereby providing an estimate of the cumulative delivered dose to targets and organs at risk. RayAdaptive uses daily treatment imaging (such as cone-beam CT (CBCT)) together with the planning CT to generate an updated representation of patient anatomy and recalculation of dose on the current patient anatomy, allowing clinicians to evaluate whether anatomical changes could meaningfully alter the planned dose distribution. These features are designed to be used in tandem. Their combined capabilities are intended to support clinical decision-making related to treatment monitoring and potential adaptation.
Treatment groups
Trial outcomes
Primary outcomes
Proportion of verification image assessments for each subject resulting in a clinical adaptive replanning decision
Defined as ordering repeat CT simulation and/or treatment plan reoptimization.
Secondary outcomes
Treating physician-reported influence of RayTracker/RayAdaptive on adaptive replanning decisions
Can I define this outcome to be: Did the RayTracker / RayAdaptive intervention influence your clinical decision? \[Yes / No\] This will be reported by physician count.
Concordance between RayAdaptive predictions of inadequate target coverage and findings on repeat CT simulation
Concordance between RayAdaptive predictions of organ-at-risk dose constraint violations and findings on repeat CT simulation
Incidence of AEs and device deficiencies
Incidence of AEs and device deficiencies at least possibly related to use of the investigational RayTracker/RayAdaptive software or its incorporation into the clinical workflow as assessed throughout the course of proton therapy and for 90 days following completion of proton treatment. Device deficiencies may include software malfunction, calculation error, deformable registration failure, software defect, or software limitations affecting treatment plan evaluation, image review, or data analysis.