PEEP Titration Guided by Electrical Impedance Tomography in Laparoscopic Surgery The PEaRL Study

Trial statusRecruiting
Trial phaseNot applicable
Trial typeInterventional
Biological sexAll
Age18+
SponsorASST Fatebenefratelli Sacco

About this trial

Background:

Laparoscopic surgery has gained widespread adoption due to its minimally invasive nature, offering advantages such as reduced postoperative pain, shorter hospitalization, and faster functional recovery compared with traditional open surgery. Nevertheless, postoperative respiratory complications remain a major source of morbidity. Factors such as general anesthesia, the Trendelenburg position, and CO₂ pneumoperitoneum can impair respiratory mechanics, reduce total lung capacity, and promote atelectasis, leading to compromised gas exchange.

Rationale:

Positive end-expiratory pressure (PEEP) is routinely applied to prevent alveolar collapse and improve oxygenation during mechanical ventilation. However, the use of standardized, non-individualized PEEP levels may be suboptimal, as inappropriate settings can cause alveolar overdistension or persistent collapse. Personalized PEEP titration, tailored to patient-specific lung mechanics, has recently emerged as a promising strategy to minimize ventilator-induced lung injury (VILI).

Methods and Tools:

Electrical Impedance Tomography (EIT) is a non-invasive, bedside monitoring technique that enables real-time assessment of regional lung ventilation. By evaluating ventilated and non-ventilated lung areas, EIT can guide PEEP optimization and support individualized ventilatory management. Recent studies suggest that EIT-guided PEEP titration improves respiratory parameters and reduces atelectasis in patients undergoing major surgery.

Objective:

The present study aims to evaluate the efficacy of EIT-guided PEEP personalization in patients undergoing laparoscopic and robotic surgery. Primary endpoints include improvements in regional ventilation, respiratory system compliance, and intraoperative gas exchange, as well as postoperative pulmonary function.

Eligibility criteria

This trial does not accept healthy volunteers

Qualifiers

scheduled for laparoscopic abdominal surgery

informed consent signed

Disqualifiers

COPD

Acute respiratory failure

Hemodynamic instability

Pregnancy

Trial design

Design model

Parallel

Treatments tested in this trial

  • A PEEP trial performed with the PulmoVista® 500 (Dräger, Lübeck, Germany) is a procedure designed to identify the optimal level of positive end-expiratory pressure

    Device

    During the trial, stepwise adjustments of PEEP are made while EIT provides real-time, bedside visualization of ventilation distribution across different lung regions. Typically, the protocol involves a recruitment maneuver followed by incremental and/or decremental PEEP steps (for example, in 2-3 cmH₂O intervals). At each step, EIT measures changes in regional impedance, which reflect variations in local lung aeration and ventilation. By analyzing these parameters, clinicians can determine the individualized "best PEEP", defined as the point at which alveolar collapse is minimized without causing significant overdistension. The optimal PEEP is then set for subsequent ventilation management.

Treatment groups

52 Participants
are divided into 2 treatment groups
Group A: Standard PEEPNo intervention 0 interventions
Group B: EIT PEEPExperimental treatment 1 intervention

Trial outcomes

Primary outcomes

1

Static respiratory system compliance

Respiratory system compliance is equivalent to tidal volume divided by the diiference between plateau and PEEP pressure. Unit of measurement is cmH2O/mL

Time frame
- Baseline (after anesthesia induction) - T1 (After Trendelemburg position and induction of pneumoperitoneum) - T2 (After PEEP trial) - T3 (90 minutes after PEEP trial) - T4 (180 minutes after PEEP trial) - T5 (Before end of anesthesia)

Secondary outcomes

Other outcomes

Sponsors and contacts