Perceptual Adaptation Following Cochlear Implantation (Aim 3a)

Trial statusRecruiting
Trial phaseNot applicable
Trial typeInterventional
Biological sexAll
Age18+
SponsorNYU Langone Health

About this trial

The goal of this study is to study the adaptation process in newly implanted Single-Sided Deaf Cochlear Implant (SSD-CI) users. Subjects will use four frequency maps for the first month after CI activation. One of these maps will be standard of care and the other three will have higher low frequency edges than the standard of care default maps. These maps will alternate daily during the first month (with exceptions made for situations when the subject is allowed to use a preferred map rather than the map predetermined for use that day), and after that point each subject will make a selection at the beginning of the week to compare all four maps and decide which one to use at the beginning of the following week. The goal of this study is to investigate how reducing place-pitch mismatch in SSD CI users affects 1) sound quality, 2) device use, and 3) speech perception.

Eligibility criteria

This trial does not accept healthy volunteers

Qualifiers

Age 18 or older

No known anatomical abnormalities in either ear

English speaking

Intends to receive a cochlear implant in one ear (or has already received it but it has not been activated).

Disqualifiers

Under age 18

Documented anatomical abnormality of the implanted ear

Non-English speaking

Greater than minimal hearing loss in the contralateral ear.

Trial design

Design model

Single group

Treatments tested in this trial

  • Alternative Frequency Mapping

    Other intervention

    Patients will have their speech processors programmed with four maps, three of which use a higher low-frequency cutoff than the default map (313 Hz, 438 Hz, 563 Hz, compared to the default map that has a low-frequency cutoff of 188 Hz).

Treatment groups

22 Participants
are divided into 1 treatment group
Group A: Newly implanted Single-Sided Deaf Cochlear Implant (SSD-CI) UsersExperimental treatment 1 intervention

Trial outcomes

Primary outcomes

1

Bilateral speech perception as measured by Bamford-Kowal-Bench (BKB-SIN) speech-in-noise score while using standard 188 Hz Frequency-Allocation Table (FAT)

The BKB-SIN speech-in-noise test measures speech perception in noise by assessing a listener's signal-to-noise ratio (SNR) loss. The test results are presented as the SNR loss, which is the amount the signal-to-noise ratio needs to be increased for the listener to correctly repeat 50% of the sentences. A higher SNR loss indicates more difficulty hearing.

Time frame
Baseline
2

Bilateral speech perception as measured by BKB-SIN speech-in-noise score while using standard 188 Hz FAT

The BKB-SIN speech-in-noise test measures speech perception in noise by assessing a listener's signal-to-noise ratio (SNR) loss. The test results are presented as the SNR loss, which is the amount the signal-to-noise ratio needs to be increased for the listener to correctly repeat 50% of the sentences. A higher SNR loss indicates more difficulty hearing.

Time frame
1 month post activation of implant
3

Bilateral speech perception as measured by BKB-SIN speech-in-noise score while using standard 188 Hz FAT

The BKB-SIN speech-in-noise test measures speech perception in noise by assessing a listener's signal-to-noise ratio (SNR) loss. The test results are presented as the SNR loss, which is the amount the signal-to-noise ratio needs to be increased for the listener to correctly repeat 50% of the sentences. A higher SNR loss indicates more difficulty hearing.

Time frame
3 months post activation of implant
4

Bilateral speech perception as measured by BKB-SIN speech-in-noise score while using standard 188 Hz FAT

The BKB-SIN speech-in-noise test measures speech perception in noise by assessing a listener's signal-to-noise ratio (SNR) loss. The test results are presented as the SNR loss, which is the amount the signal-to-noise ratio needs to be increased for the listener to correctly repeat 50% of the sentences. A higher SNR loss indicates more difficulty hearing.

Time frame
6 months post activation of implant

Secondary outcomes

1

Sound Quality Survey score while using standard 188 Hz FAT

The Sound Quality Survey records subjective thoughts regarding sound quality, listening effort and intelligibility with all four maps at various time points. The survey was created for this study and consists of 4 questions address speech understanding, listening effort, sound quality, and music when the CI is ON versus when the CI is off. Items are rated from 1 (worst) to 9 (best). Scores range from 4-36, higher scores indicate better overall sound quality when the CI is on. Participants will provide a separate answers for each of the 4 maps.

Time frame
Baseline
2

Sound Quality Survey score while using standard 188 Hz FAT

The Sound Quality Survey records subjective thoughts regarding sound quality, listening effort and intelligibility with all four maps at various time points. The survey was created for this study and consists of 4 questions address speech understanding, listening effort, sound quality, and music when the CI is ON versus when the CI is off. Items are rated from 1 (worst) to 9 (best). Scores range from 4-36, higher scores indicate better overall sound quality when the CI is on. Participants will provide a separate answers for each of the 4 maps.

Time frame
1 month post activation of implant
3

Sound Quality Survey score while using standard 188 Hz FAT

The Sound Quality Survey records subjective thoughts regarding sound quality, listening effort and intelligibility with all four maps at various time points. The survey was created for this study and consists of 4 questions address speech understanding, listening effort, sound quality, and music when the CI is ON versus when the CI is off. Items are rated from 1 (worst) to 9 (best). Scores range from 4-36, higher scores indicate better overall sound quality when the CI is on. Participants will provide a separate answers for each of the 4 maps.

Time frame
3 months post activation of implant
4

Sound Quality Survey score while using standard 188 Hz FAT

The Sound Quality Survey records subjective thoughts regarding sound quality, listening effort and intelligibility with all four maps at various time points. The survey was created for this study and consists of 4 questions address speech understanding, listening effort, sound quality, and music when the CI is ON versus when the CI is off. Items are rated from 1 (worst) to 9 (best). Scores range from 4-36, higher scores indicate better overall sound quality when the CI is on. Participants will provide a separate answers for each of the 4 maps.

Time frame
6 months post activation of implant

Other outcomes

Sponsors and contacts

Click on the lead sponsor to view all of their trials.

NYU Langone Health

Lead sponsor

National Institute on Deafness and Other Communication Disorders (NIDCD)