PERFECT - Portuguese Evolut Registry Studying the Outcomes of Medtronic Evolut™ FX+ TAVI System by Evaluating an Optimal Care Pathway for TAVI

Trial statusRecruiting
Trial phaseNot listed
Trial typeObservational
Biological sexAll
Age18+
SponsorPortuguese Association of Interventional Cardiology

About this trial

The goal of this registry is to learn how the Medtronic Evolut™ FX+ transcatheter aortic valve implantation (TAVI) System performs in adults with severe, symptomatic aortic stenosis who need valve replacement.

The main questions it aims to answer are:

* Can using a standardized procedure for the impantation of the Medtronic Evolut™ FX+ TAVI System increase safety and efficiency? * What are the short-term (30 days) and long-term (1 year) patient outcomes, including the need for a pacemaker, complications, and valve function?

Participants will undergo TAVI with the Medtronic Evolut™ FX+ TAVI System as part of their routine care.

Be followed during their hospital stay, at 30 days, and at 1 year to check heart health, valve function, and recovery. 500 people at 12 hospitals in Portugal will take part in this registry.

Eligibility criteria

This trial does not accept healthy volunteers

Qualifiers

Severe symptomatic (defined as New York Heart Association (NYHA) class ≥ II) aortic stenosis (AS), including but not limited to: Dyspnea at rest or on exertion, fatigue, angina, syncope in the absence of another identifiable cause;

Subjects provided written Informed Consent as approved by the Ethics Committee (EC);

Disqualifiers

Subjects with pre-existing surgical bioprosthetic aortic valve;

Hepatic insufficiency (Child-Pugh Class B or C);

Contraindicated for treatment with the Medtronic Evolut™ FX+ TAVU System in accordance with the Instructions for Use (IFU);

Anatomically considered not suitable for the Medtronic Evolut™ FX+ TAVI system;

Trial population

The study population includes patients with severe, symptomatic AS with indication for TAVI, who meet the criteria for use of the Medtronic EvolutTM FX+ System in accordance with IFU and local regulations.

Trial design

Design model

Cohort

Time perspective

Prospective

Treatments tested in this trial

Not listed

Trial groups

500 Participants
are grouped into 1 trial group
Group A: Patients with severe aortic stenosis undergoing Medtronic Evolut FX+ TAVI System

Trial outcomes

Primary outcomes

1

VARC-3 technical success

A composite outcome assessed immediately after the TAVI procedure, including: survival, successful vascular access and device deployment/retrieval, correct positioning of a single valve, and freedom from major complications or need for surgery/intervention (excluding pacemaker).

Time frame
Immediately after the index procedure

Secondary outcomes

1

Rate of Permanent Pacemaker Implantation (PPI)

Percentage of participants who require a new permanent pacemaker due to new or worsening conduction disturbances.

Time frame
30 days after procedure
2

Length of Hospital Stay

Number of days from TAVI procedure to discharge.

Time frame
Up to 30 days after procedure
3

All-Cause Mortality

Death from any cause.

Time frame
30 days and 1 year
4

Stroke

Any new neurologic deficit classified as a stroke by clinical evaluation.

Time frame
30 days and 1 year

Other outcomes

1

Procedural Technique Compliance (TAVI.PTrainer Survey)

Assessment of operator adherence to standardized TAVI procedural steps, including Cusp Overlap Technique, using a dedicated checklist tool.

Time frame
During the index procedure
2

Correlation of Procedural Compliance with Clinical Outcomes

Analysis of whether higher compliance with optimized TAVI procedural steps is associated with better patient outcomes.

Time frame
Procedure through 1 year

Sponsors and contacts

Click on the lead sponsor to view all of their trials.