About this trial
This is a single-center, prospective, randomized crossover physiological trial conducted in elderly patients (≥65 years) with septic shock in the intensive care unit (ICU). All enrolled patients receive sequential titration of mean arterial pressure (MAP) to three predefined target ranges (60-65 mmHg, 65-70 mmHg, and 70-75 mmHg) in randomized order. The primary objective is to compare tissue perfusion pressure (TPP) between the low and intermediate MAP targets, and to test the non-inferiority hypothesis that the lower MAP target is non-inferior to the intermediate target. Multiple secondary microcirculatory, systemic perfusion, and safety indicators are collected during steady-state hemodynamic periods under each MAP target stage. Researchers will adopt linear mixed-effects models to analyze intra-individual differences across blood pressure targets and explore the MAP threshold for optimal peripheral perfusion. Safety outcomes including adverse hemodynamic events and long-term clinical follow-up data will also be assessed.
Eligibility criteria
This trial does not accept healthy volunteersQualifiers
Elderly patients (≥65 years) admitted to ICU with septic shock requiring invasive arterial blood pressure monitoring and vasopressor support.
Clinically indicated target mean arterial pressure (MAP) range covering 60-75 mmHg.
Expected duration of stable hemodynamic status ≥ 150 minutes to complete the crossover titration protocol.
Attending intensivist agrees to participate; written informed consent obtained from patient or legally authorized representative.
Disqualifiers
Age < 65 years.
Severe aortic stenosis, aortic dissection, or uncontrolled intracranial hypertension requiring fixed high MAP target.
Known irreversible terminal condition with expected survival < 72 hours.
Severe active bleeding requiring massive transfusion with ongoing hemodynamic instability.
Trial design
Crossover
Treatments tested in this trial
Ascending MAP titration sequence
Other intervention【Ascending MAP titration sequence】 Sequential adjustment of target mean arterial pressure: 60-65 mmHg → 65-70 mmHg → 70-75 mmHg. Each target level is maintained for fixed observation duration.
Descending MAP titration sequence
Other intervention【Descending MAP titration sequence】 Sequential adjustment of target mean arterial pressure: 70-75 mmHg → 65-70 mmHg → 60-65 mmHg. Each target level is maintained for fixed observation duration.
Treatment groups
Trial outcomes
Primary outcomes
Mean difference in Tissue Perfusion Pressure (TPP) between MAP target 60-65 mmHg and 65-70 mmHg
Mean Arterial Pressure (MAP) is the primary hemodynamic target. Tissue Perfusion Pressure (TPP) is calculated as MAP minus microvascular critical closing pressure (Pcc). Primary non-inferiority endpoint: ΔTPP = Mean TPP at 60-65 mmHg minus mean TPP at 65-70 mmHg (unit: mmHg). Non-inferiority margin set at -4 mmHg; non-inferiority is confirmed if the lower bound of one-sided 95% CI of ΔTPP ≥ -4 mmHg. TPP is calculated as MAP minus microvascular critical closing pressure (Pcc) using routine invasive arterial waveform data, no extra invasive procedures added.
Secondary outcomes
Perfusion Gain Efficiency (PGE) at low and high MAP intervals
Mean Arterial Pressure (MAP) is the primary hemodynamic target. Tissue Perfusion Pressure (TPP) is calculated as MAP minus microvascular critical closing pressure (Pcc). Perfusion Gain Efficiency (PGE) is calculated as the slope of linear regression between MAP and TPP within each MAP interval (60-65, 65-70, 70-75 mmHg), reflecting the efficiency of MAP elevation in improving tissue perfusion. PGE \> 1 indicates efficient perfusion conversion; PGE ≤ 0 indicates plateau effect.
Coefficient of variation of microvascular critical closing pressure (Pcc) across three MAP target intervals
Mean Arterial Pressure (MAP) is the primary hemodynamic target. Tissue Perfusion Pressure (TPP) is calculated as MAP minus microvascular critical closing pressure (Pcc). Intra-individual variability of Pcc measured at 60-65, 65-70, 70-75 mmHg MAP stages, expressed as coefficient of variation (CV).
Automated capillary refill time (aCRT) at three MAP target levels
Mean Arterial Pressure (MAP) is the primary hemodynamic target. Standardized objective automated capillary refill time (aCRT) is measured via Mindray V700 monitor peripheral perfusion module at each stable MAP stage.
Other outcomes
Inflection point of MAP-TPP dose-response curve
Mean Arterial Pressure (MAP) is the primary hemodynamic target. Tissue Perfusion Pressure (TPP) is calculated as MAP minus microvascular critical closing pressure (Pcc). Segmented linear regression to identify the MAP threshold where TPP perfusion gain plateaus or declines across 60-65, 65-70, 70-75 mmHg intervals.
Locations
Sponsors and contacts
Click on the lead sponsor to view all of their trials.
This trial is not recruiting at the moment. You can still explore other options: