About this trial
Intraventricular conduction delay alone or in combination with AV conduction delay is associated with a dyssynchronous activation of the ventricles and may result in LV function impairment.
Conduction system pacing can restore physiologic ventricular activation in the presence of intraventricular and atrioventricular conduction delays.
Patients with intraventricular conduction delay alone or in combination with AV conduction delay who have a permanent pacemaker indication due to intermittent bradycardia and have predominantly intact AV conduction may benefit from continuous CSP.
Eligibility criteria
This trial does not accept healthy volunteersQualifiers
age > 18 years
Any indication for cardiac pacing with an expected VP burden ≤ 10% after 1- month run-in period
Baseline wide QRS (≥150 ms) with normal PR or QRS ≥ 130 ms + PR≥230 ms
LVEF≥50%
Disqualifiers
Pregnant woman
Permanent or long-lasting atrial fibrillation
Previous PM/ICD
Unstable angina, acute Myocardial Infarction (MI), Coronary Artery Bypass Graft (CABG), Percutaneous Coronary Angioplasty (PCI), surgical valve repair or replacement within 90 days prior enrollment
Trial design
Crossover
Treatments tested in this trial
Pacemaker implant
DeviceAll patients will receive a ventricular lead in the conduction system (HBP or LBBAP) using conventional implant techniques described elsewhere. The pacemaker device and leads should be implanted according to the physician's manual provided with the devices. Only locally approved Medtronic PM generators with MVP algorithms will be used during the study. Investigators will use the Medtronic Select Secure 3830 lead for CSP. Acceptable LBBAP threshold should be \<2,5V@0,5ms. Other commercially available stylet driven leads may be used as bail-out strategy only when CSP cannot be achieved with the 3830 lead at the implanting physician discretion. During the implant procedure lead impedances, pacing and sensing parameters will be measured using a pacing system analyzer (PSA). It is strongly encouraged the designation of a single and experienced CSP implanting physician at each center.
Treatment groups
Trial outcomes
Primary outcomes
Percentage of patients with LVEF decrease ≥10% and/or ≥ 15% decrease in GLS at 12-month follow-up measured by echocardiographic evaluation
Percentage of patients with LVEF decrease ≥10% and/or ≥ 15% decrease in GLS at 12-month follow-up measured by echocardiographic evaluation
Sponsors and contacts
Click on the lead sponsor to view all of their trials.
Óscar Cano Pérez
Lead sponsor
Spanish Society of Cardiology
Sponsor institution