About this trial
When the flow of blood ejected by the heart drops significantly, that is to say when there is "shock", one of the first treatments undertaken is often volume expansion. This treatment consists of injecting a liquid intravenously, generally in the form of a bolus, that is to say a dose of solute administered all at once, of 250 to 500 mL of fluid over approximately 10 to 30 minutes. The injected fluid expands the blood volume and fills the heart pump, in order to increase the flow it ejects.
However, this treatment poses two problems. First, it is only inconsistently effective. It is possible that of the 250-500 mL of fluid administered in the standard way, only a part is effective, whereas, as the effectiveness decreases during the infusion, the rest does not increase cardiac output significantly.
However, the average part of the total volume that is ineffective on a large population of patients is not well known.
Second, the effects of volume expansion on cardiac output decrease rapidly after the end of administration. However, the average duration of effectiveness of a 250-500 mL fluid bolus, and the factors that influence this duration of effectiveness, are not well determined.
The main objective of this research is to measure, among the volume of a fluid bolus, which part does not significantly increase cardiac output. The secondary objective is to measure the average time of effectiveness after the end of the infusion and the factors that influence it.
Eligibility criteria
This trial does not accept healthy volunteersQualifiers
Age ≥18 years old
Hospitalisation in intensive care
Haemodynamic monitoring already in place with a pulse wave contour analysis-derived estimation of cardiac output (either calibrated or uncalibrated)
Decision taken by the clinicians in charge of the patient to perform volume expansion by intravenous infusion of a 6 mL/kg crystalloid bolus
Disqualifiers
Pregnancy
Refusal to participate by relatives of the patient or the patient himself
Other therapeutic modification during volume expansion
Trial population
Patients hospitalized in intensive care unit and with shock for whom a fluid challenge is administered
Trial design
Cohort
Prospective
Treatments tested in this trial
fluid challenge
DrugFluid bolus of 500 mL of crystalloids given at a constant rate between 10 and 15 minutes
Treatment groups
Trial outcomes
Primary outcomes
To measure, during the administration of a fluid bolus in order to perform volume expansion, the volume of fluid which causes an increase in cardiac output of less than 15%.
We will measure, among the volume administered (500mL), the proportion of infused volume which allowed an increase in cardiac output ≥15% compared to the baseline value. This baseline value will be defined by the average measured over the minute preceding the start of the fluid infusion
Secondary outcomes
The maximum amplitude of the change induced by volume expansion in cardiac output, mean arterial pressure and central venous pressure
The maximum amplitude, expressed as an absolute value and as a percentage of the baseline value, as defined above, of the change induced by volume expansion in cardiac output, mean arterial pressure and central venous pressure
The delay at which this maximum effect appears in terms of cardiac output, mean arterial pressure and central venous pressure
The time following the end of the infusion from which the cardiac output becomes ≤5% of the baseline value
The factors that influence these pharmacokinetic variables will be determined
Sponsors and contacts
Click on the lead sponsor to view all of their trials.