About this trial
Obstructive sleep apnea (OSA) is a common condition in which the airway repeatedly collapses during sleep, leading to poor sleep quality and reduced oxygen levels. Hypoglossal nerve stimulation (HGNS) is an approved treatment that uses a small implanted device to stimulate the genioglossus muscle and keep the airway open. However, some patients continue to have OSA despite using HGNS. Atomoxetine and oxybutynin, "AtoOxy", is a promising pharmacologcal therapy under investigation that has been shown to activate pharyngeal muscles-in particular non-genioglossus muscles--but appears more efficacious in some patients than others.
This study will test whether the combination of AtoOxy and HGNS can further improve breathing during sleep compared to either monotherapy alone. Participants with OSA and an HGNS device will be randomized to receive, in random order: HGNS+AtoOxy, HGNS alone (plus placebo), AtoOxy alone (HGNS device off), and placebo (HGNS device off), in a cross-over trial.
The main goal is to determine whether the combined treatment reduces the number of breathing events during sleep; the primary outcome test will compare HGNS+AtoOxy versus HGNS alone. The effect of each intervention versus placebo will also be presented.
The study will also examine how individual patient characteristics influence response to treatment.
Eligibility criteria
This trial does not accept healthy volunteersQualifiers
Ages 18 - 79 years
Diagnosed OSA
Implantation of a hypoglossal nerve stimulation device (HGNS, Inspire Medical) or scheduled for implantation (implantation required for randomization)
Willingness to withhold HGNS while testing therapies (up to 6 weeks with HGNS off [with/without pharmacotherapy] to assess benefits of HGNS therapy).
Disqualifiers
Any uncontrolled medical condition
Current use of the medications under investigation.
Issues relating to short-term withdrawal of HGNS therapy
Excluded: Occupational driving (truck drivers, fork-lift operation, taxi/uber drivers)
Trial design
Crossover
Treatments tested in this trial
Combination device and drug: Unilateral hypoglossal nerve stimulation & atomoxetine-plus-oxybutynin (HGNS+AtoOxy)
Other interventionElectrical stimulation of the hypoglossal nerve using an implanted device (Inspire Medical Systems) to activate upper airway dilator muscles during sleep at prescribed therapeutic settings. Atomoxetine 80 mg administered orally at bedtime. Oxybutynin 5 mg administered orally at bedtime. Dose escalation with half-dose for initial 3 nights followed by full dose.
Unilateral hypoglossal nerve stimulation (HGNS), active comparator condition
DeviceElectrical stimulation of the hypoglossal nerve using an implanted device (Inspire Medical Systems) to activate upper airway dilator muscles during sleep at prescribed therapeutic settings. Matching placebo capsules administered orally at bedtime.
Atomoxetine-plus-oxybutynin (80/5 mg) (AtoOxy), active comparator condition
DrugAtomoxetine 80 mg administered orally at bedtime. Oxybutynin 5 mg administered orally at bedtime. Dose escalation with half-dose for initial 3 nights followed by full dose. HGNS device off
Placebo; placebo comparator condition
DrugMatching placebo capsules administered orally at bedtime. HGNS device off
Treatment groups
Trial outcomes
Primary outcomes
Apnea-Hypopnea Index
Apnea-hypopnea index (AHI), defined as the number of apneas and hypopneas per hour of sleep, measured by overnight polysomnography at the end of each treatment period. Quantitative outcome variable: percent change (symmetrized) from baseline.
Secondary outcomes
Hypoxic Burden
Hypoxic burden, defined as the area under the oxygen desaturation curve associated with respiratory events multiplied by event frequency, measured during overnight polysomnography. Quantitative outcome variable: percent change (symmetrized) from baseline.
Visual Analog Scale for Sleep Quality
Self-reported sleep quality measured using a visual analog scale. Quantitative outcome variable: absolute change from baseline. Range: 0-10 (higher values indicate greater sleep quality).
Other outcomes
Epworth Sleepiness Scale (ESS)
Daytime sleepiness assessed using the Epworth Sleepiness Scale (range 0-24, higher scores indicate greater sleepiness). Quantitative outcome variable: absolute change from baseline.
Visual Analog Scale for Treatment Satisfaction
Self-reported treatment satisfaction measured using a visual analog scale. Quantitative outcome variable: absolute value on treatment. Range: 0-10 (higher values indicate greater treatment satisfaction).
Sleep Apnea Quality of Life Index (SAQLI)
Disease-specific quality of life assessed using the Sleep Apnea Quality of Life Index. Quantitative outcome variable: absolute change from baseline. Range: 1-7 (higher values indicate greater sleep apnea-related quality of life).
PROMIS Sleep-Related Impairment
Patient-reported outcomes assessing sleep-related impairment: Quantitative outcome variable: absolute change from baseline. Range: 0-100 (mean 50, SD 10; higher T-scores indicate greater impairment).