About this trial
The aim for this clinical trial is to evaluate if colchicine in addition to standard of care improves insulin sensitivity in individuals with type 1 diabetes, systemic low-grade inflammaiton and reduced insulin sensitivity. The insulin sensitivity will be evaluated by a hyperinsulinemic, euglycemic clamp.
Eligibility criteria
This trial does not accept healthy volunteersQualifiers
Type 1 diabetes for more than five years according to World Health Organization criteria and c-peptid <200 pmol/L
Age 18-80 years
User of a continuous glucose monitor (CGM) system
Glycated hemoglobin A1c (HbA1c) 42-75 mmol/mol
Disqualifiers
Hypoglycaemia unawareness (inability to register low blood glucose) ad modum Pedersen-Bjergaard, 24 unless the individual uses a continuous glucose monitor with alarm function
Liver disease with elevated plasma alanine aminotransferase (ALT) > three times the upper limit of normal (measured at screening visit with the possibility of one repeat analysis within seven days, and the last measured value as being conclusive)
History of cirrhosis, chronic active hepatitis, or severe hepatic disease
Inflammatory bowel disease or chronic diarrhoea
Trial design
Crossover
Treatments tested in this trial
Colchicin 0.5 mg once daily for two weeks, then twice daily for two weeks
DrugColchicine treatment in the first period
Placebo once daily for two weeks, then twice daily for two weeks
DrugPlacebo treatment in the first period
Colchicine tablet 0.5 mg once-daily for two weeks, then twice daily for two weeks
DrugColchicine treatment in the second period
Placebo once daily for two weeks, then twice daily for two weeks
DrugPlacebo treatment in the second period
Treatment groups
Trial outcomes
Primary outcomes
Mean difference in M-value
Mean difference in insulin sensitivity is measured by the M-value (glucose infusion rate mg/kg/min) during the last 30 minutes of a 180 minutes hyperinsulinemic euglycemic clamp procedure using insulin infusion rate of 60 mU/m²/min
Secondary outcomes
Mean difference in M-value
Measured in mg/m²/min. Adjusted to body surface area (BSA)
Mean difference in M-value (adjusted to fat free mass (FFM))
Measured in mg/kg FFM/min
Mean difference in Insulin Sensitivity Index (ISI)
Glucose infusion rate / Plasma insulin in steady state
Mean difference in average daily insulin dosage
Units/day. Total daily dose, short acting, long acting
Other outcomes
Mean difference in respiratory exchange ratio between basal state and during clamp
Ratio
Adipocyte tissue biopsies
Ratio. Fold difference in Adipocyte size, Inflammation, Glucose metabolism, Extracellular matrix, Oxygen consumption, Transcriptomics, Proteomics
Time spent in target blood glucose range (3.9 - 10 mmol/L) evaluated by a continous glucose monitor (CGM)
Measured in % of 24 hours.
Time spent in tight range (3.9 - 7.8 mmol/L) evaluated by a continous glucose monitor (CGM)
Measured in % of 24 hours.
Sponsors and contacts
Click on the lead sponsor to view all of their trials.
Asger Lund, MD
Lead sponsor
University Hospital, Gentofte, Copenhagen
Sponsor institution
University of Copenhagen
Collaborator