About this trial
This is a single-centre, randomized, double-blinded controlled non-inferiority trial that will be conducted at the Orthopaedic Department at Uppsala University Hospital, Uppsala. The aim of the study is to evaluate the performance of a dual mobility acetabular component with a Vitamin E-infused highly crosslinked polyethylene (VEPE) liner compared to a conventional polyethylene (PE) liner in adult patients with symptomatic osteoarthritis, osteonecrosis, or dysplasia of the hip requiring a hip replacement. The assessments will focus on early wear, cup migration, adverse events, and clinical outcomes. Measurements will be conducted using Computed Tomography Radiostereometric Analysis (CT-RSA) instead of traditional radiostereometric analysis. The study hypothesis is that the PE liner will be non-inferior to the VEPE liner in terms of early wear over a two-year period.
Eligibility criteria
This trial does not accept healthy volunteersQualifiers
Age 18-75 years
Written informed consent
Eligible for a Total Hip Arthroplasty according to local guidelines and appropriate candidate for a dual mobility concept
Diagnosis: Symptomatic osteoarthritis, osteonecrosis, or dysplasia of the hip requiring a hip replacement
Disqualifiers
Confirmed dementia or cognitive impairment
Unwillingness to give written informed consent
Age <18 or >75 years
Hip fracture (traumatic or pathological) in need of a Total Hip Arthroplasty
Trial design
Parallel
Treatments tested in this trial
Total Hip Arthroplasty
DeviceAll patients will be operated with an anterolateral or posterior approach using a cemented or uncemented cup (BiMobile, Waldemar Link GmbH, Hamburg, Germany).
Treatment groups
Trial outcomes
Primary outcomes
Wear performance
To compare the in vivo wear performance of a VEPE liner versus a conventional PE liner using CT-RSA in patients undergoing total hip arthroplasty with a dual mobility cup.
Secondary outcomes
Long-term wear performance
To evaluate the in vivo wear performance of the VEPE liner versus the conventional PE liner using CT-RSA.
Cup stability
To evaluate stability of the cup by measuring degree of migration using CT-RSA.
Harris Hip Score
Harris Hip Score (HHS), a clinician-completed tool scored from 0 to 100, will be used to evaluate hip function, pain, and mobility after hip replacement.
Hip Disability and Osteoarthritis Outcome Score
The Hip Disability and Osteoarthritis Outcome Score (HOOS), a 40-item, patient-reported questionnaire, will be used to assess the participant's opinions about their hip symptoms and functional limitations.
Sponsors and contacts