TRanscAtheter TreatMent of PurE Aortic Regurgitation With VitaFlow Liberty System

Trial statusRecruiting
Trial phasePhase 4
Trial typeInterventional
Biological sexAll
Age60+
SponsorRuijin Hospital

About this trial

This study is a prospective, multicenter, non-randomized controlled trial, planning to enroll 180 patients with pure native aortic regurgitation. On the basis of standardized medical therapy, patients will be assigned in a 1:1 ratio to undergo transfemoral transcatheter aortic valve replacement (TF-TAVR) . This prospective, multicenter trial aims to evaluate the safety and effectiveness of transfemoral TAVR using the VitaFlow™ self-expanding valve system compared to dedicated transcatheter devices in patients with PNAR.

The primary endpoint is a composite of all-cause mortality, disabling stroke, and rehospitalization for heart failure, myocardial Infarction, and requiring dialysis or valve reoperation at 12 months post-procedure.

Secondary endpoints include procedure-related complications, long-term clinical events, patient functional status and quality of life, bioprosthetic valve imaging follow-up, echocardiographic parameters, and treatment costs. All endpoint definitions conform to the Valve Academic Research Consortium-3 (VARC-3) criteria

Eligibility criteria

This trial does not accept healthy volunteers

Qualifiers

None

Disqualifiers

None

Trial design

Design model

Parallel

Treatments tested in this trial

  • VitaFlow+GDMT

    Combination product

    The patient will undergo transcatheter aortic valve replacement on the basis of guideline-directed medical therapy with The VitaFlow™ system. The VitaFlow™ system (MicroPort®, Shanghai, China) was a novel TAVR system, which incorporates high-radial force and a double layer polyethylene terephthalate (PET) skirt to optimize frame geometry and minimize the risks of paravalvular leak (PVL). The VitaFlow™ transcatheter aortic valve is made of a self-expanding nitinol frame and tri-leaflet bovine pericardial valve.

  • J-Valve+GDMT

    Combination product

    The patient will undergo transfemoral aortic valve replacement on the basis of guideline-directed medical therapy with The J-Valve system (Jie ChengMedical Technologies, Suzhou, China). The J-Valve system is a second-generation self-expand able device composed of a porcine bioprosthetic aortic valve and a transfemoral delivery sheath. The valve is supported by a self-expanding nitinol structure. The different valve sizes are 21, 23, 25, 27, 29 and 34 mm. Three U-shaped nitinol graspers were designed to surround the valve.

Treatment groups

120 Participants
are divided into 2 treatment groups
Group A: VitaFlowExperimental treatment 1 intervention
Group B: J-ValveActive comparator 1 intervention

Trial outcomes

Primary outcomes

1

Clinical worsening

The primary endpoint is a composite of all-cause mortality, disabling stroke, and rehospitalization for heart failure, myocardial Infarction, and requiring dialysis or valve reoperation at 12 months post-procedure.

Time frame
12 months

Secondary outcomes

1

Rate of procedural complications

The rate of any aortic dissection, annular rupture, coronary artery occlusion, vascular complications, permanent pacemaker implantation, reoperation of heart valve.

Time frame
12 months
2

6-minute walk distance

This test measures the distance that a patient can quickly walk on a flat, hard surface in a period of 6 minutes.

Time frame
12 months
3

New York Heart Association (NYHA) functional class

Classification of function capacity of the NYHA.

Time frame
12 months
4

Rate of hypoattenuated leaflet thickening

The rate of hypoattenuated leaflet thickening. Hypoattenuated leaflet thickening(HALT)defined by VARC-3

Time frame
12 months

Other outcomes

1

Left ventricular ejection fraction (Simpson's method)

Transthoracic echocardiography measurement of left ventricular ejection fraction (Simpson's method). Unit: %

Time frame
12 months
2

Left ventricular end-diastolic volume index

Transthoracic echocardiography measurement left ventricular end-diastolic volume index (LVEDVi). Unit: milliliters per square meter (mL/m²)

Time frame
12 months
3

Left ventricular end-systolic volume index

Transthoracic echocardiography measurements of left ventricular end-systolic volume index (LVESVi). Unit: milliliters per square meter (mL/m²)

Time frame
12 months
4

Left ventricular end-diastolic diameter

Transthoracic echocardiography measurements of left ventricular end-diastolic diameter (LVEDd). Unit: millimeters

Time frame
12 months