Post-market Surveillance of Micorport CRM Cardiac Implantable Electronic Devices

Trial statusRecruiting
Trial phaseNot listed
Trial typeObservational
Biological sexAll
Age18-90
SponsorMicroPort CRM

About this trial

The primary objective of the study is to assess the chronic safety of MicroPort CRM market-released systems.

Eligibility criteria

This trial does not accept healthy volunteers

Qualifiers

ENO, TEO, OTO, ALIZEA, BOREA, or CELEA PM single chamber (SR) or dual chamber (DR) implanted after 01 January 2020 in combination with at least one XFINE or VEGA pacing lead

ULYS, EDIS ICD single chamber (VR) or dual chamber (DR) system in combination with an INVICTA defibrillation lead. Additional XFINE or VEGA atrial pacing lead is optional.

GALI CRT-D implanted in combination with an INVICTA defibrillation lead. Additional NAVIGO left ventricular pacing lead is optional.

GALI SONR CRT-D in combination with an INVICTA defibrillation lead and with either a NAVIGO left ventricular or a SONRTIP atrial pacing lead.

Disqualifiers

Age less than 18 years old or more than 90 years at time of inclusion, incapacitated or under guardianship or kept in detention

Life expectancy less than 1 year

Currently enrolled in an active study of MicroPort CRM

Trial population

Subjects implanted with a pacemaker, an Implantable Cardioverter-Defibrillator (ICD) or a Cardiac Resynchronization Therapy (CRT-D) Class I or II indication according to the latest guidelines from the European Society of Cardiology (ESC)1 or from the American College of Cardiology (ACC)/ American Heart Association (AHA)/ Heart Rhythm society (HRS)2 as appropriate per geography.

Trial design

Design model

Cohort

Time perspective

Prospective

Treatments tested in this trial

  • Implantation of a CIED

    Device

    Implantation of a CIED

Treatment groups

2,500 Participants
are divided into 3 treatment groups
Group A: Pacemaker system1 intervention
Group B: ICD system1 intervention
Group C: CRT-D system1 intervention

Trial outcomes

Primary outcomes

1

Chronic complication free rate of MicroPort CRM market-released system

Complications are defined as device-related reinterventions or deaths

Time frame
Through study duration, an average of 5 years

Secondary outcomes

1

Acute complication free rate

Complications are defined as device-related reinterventions or deaths

Time frame
Up to 3 months post-implant
2

Overall complication free rate

Complications are defined as device-related reinterventions or deaths

Time frame
Through study duration, an average of 5 years
3

Annual complication free rate

Complications are defined as device-related reinterventions or deaths

Time frame
Through study duration, an average of 1 year

Other outcomes

Sponsors and contacts

Click on the lead sponsor to view all of their trials.