Press-Fit vs Loose-Fit Radial Head Arthroplasty

Trial statusRecruiting
Trial phaseNot applicable
Trial typeInterventional
Biological sexAll
Age18+
SponsorAdventHealth

About this trial

This study compares two types of artificial implants used to replace a broken part of the elbow (the radial head) when the bone is too damaged to repair. One implant (press-fit) is designed to grip the bone tightly so bone grows into it and holds it in place. The other implant (loose-fit) has a smooth stem that sits loosely in the bone and is meant to move slightly. Both implants are already approved and widely used; doctors do not yet know if one works better than the other. People taking part are placed by chance into one of the two implant groups. The study will follow them for at least 2 years to see how far they can bend and straighten the elbow, how much pain they have, how well the elbow works in daily life, whether the implant stays in good position on X-rays, and whether any further surgery is needed.

Eligibility criteria

This trial does not accept healthy volunteers

Qualifiers

Age 18 years or older.

Scheduled for primary RHA.

Willing and able to provide written informed consent.

Willing and able to comply with post-operative follow-up visits at 3 months, 6 months, 1 year, and 2 years.

Disqualifiers

Severe osteoarthritis affecting elbow function

Rheumatoid arthritis or other autoimmune disorders affecting musculoskeletal function

Full-thickness cartilage lesion in the elbow joint

Neurological or vascular complications

Trial design

Design model

Parallel

Treatments tested in this trial

  • Skeletal Dynamics Radial Head (Press-Fit)

    Device

    Skeletal Dynamics Radial Head (Press-Fit). Surgical placement of a press-fit radial head prosthesis sized for interference fit within the radial canal.

  • Stryker Radial Head (Loose-Fit).

    Device

    Surgical placement of a smooth-stem radial head prosthesis functioning as a spacer permitting rotation and micromotion.

Treatment groups

130 Participants
are divided into 2 treatment groups
Group A: Press-Fit Radial Head ArthroplastyExperimental treatment 1 intervention
Group B: Loose-Fit Radial Head ArthroplastyActive comparator 1 intervention

Trial outcomes

Primary outcomes

1

Elbow Flexion-Extension Arc of Motion

Total arc of elbow flexion-extension in degrees (maximum flexion minus loss of extension), measured with a goniometer. The primary comparison between groups is at 24 months postoperatively. Measurements at earlier time points are reported to describe recovery over time.

Time frame
Baseline, 3 months, 6 months, 12 months, and 24 months postoperatively

Secondary outcomes

1

Forearm Rotation Arc of Motion

Total arc of forearm rotation in degrees (maximum pronation plus maximum supination), measured with a goniometer.

Time frame
Baseline, 3, 6, 12, and 24 months postoperatively
2

Quick Disabilities of the Arm, Shoulder and Hand (QuickDASH) Score

The QuickDASH is an 11-item patient-reported questionnaire assessing upper extremity function and symptoms. Scores range from 0 to 100, and higher scores indicate greater disability (worse outcome).

Time frame
Baseline (preoperative), 3, 6, 12, and 24 months postoperatively
3

Mayo Elbow Performance Score (MEPS)

The MEPS assesses elbow pain, range of motion, stability, and ability to perform daily activities. Scores range from 0 to 100, and higher scores indicate better elbow function (better outcome).

Time frame
Baseline (preoperative), 3, 6, 12, and 24 months postoperatively
4

Visual Analog Scale (VAS) for Pain

Participants mark their pain intensity on a continuous line scored from 0 (no pain) to 10 (worst imaginable pain). Higher scores indicate worse pain.

Time frame
Baseline, 3, 6, 12, and 24 months postoperatively

Other outcomes

Sponsors and contacts

Click on the lead sponsor to view all of their trials.

AdventHealth

Lead sponsor

Hospital Universitario La Paz

Collaborator