About this trial
Mortality prediction in neurocritical care relies on scores computed at admission, which cannot update as the clinical course evolves. We previously developed a landmark-based machine learning model that converts hourly physiological data, including intracranial pressure, into an updating risk of death. The model was developed in a large public database and validated retrospectively in a second, independent one. This prospective multicentre study will test the model in consecutive patients at participating hospitals in Fujian Province, China. Physiological data will be collected as part of routine care. The model will generate risk estimates that are recorded for analysis but not shown to treating clinicians, and no treatment decision will be influenced by the study. The primary analysis will assess discrimination and calibration of the model for death during the intensive care stay. Secondary analyses will compare the model with severity scores in routine use and examine performance by aetiology.
Eligibility criteria
This trial does not accept healthy volunteersQualifiers
Age 18 years or older
Continuous intracranial pressure monitoring for at least 24 hours
Diagnosis of traumatic brain injury, aneurysmal subarachnoid haemorrhage or intracerebral haemorrhage
Written informed consent from the patient or a legal representative
Disqualifiers
Incomplete or unusable intracranial pressure recordings
Loss to follow-up or unavailable outcome information
Pre-existing severe neurological disease that would confound assessment
Trial population
Adults in intensive care units of participating hospitals who require continuous intracranial pressure monitoring after acute brain injury.
Trial design
Cohort
Prospective
Treatments tested in this trial
Landmark machine learning mortality prediction model
Diagnostic testObservational application of a fixed prediction model to hourly physiological data; no treatment is assigned or withheld.
Treatment groups
Trial outcomes
Primary outcomes
Area under the receiver operating characteristic curve (range 0 to 1) for death during the intensive care stay at the 24-hour landmark
Discrimination of the locked landmark model, quantified as the area under the receiver operating characteristic curve, where 0.5 indicates no discrimination and 1.0 perfect discrimination. Death is ascertained from the medical record and the curve is estimated with a 95% confidence interval
Secondary outcomes
Area under the receiver operating characteristic curve (range 0 to 1) for death during the intensive care stay at the 48-hour and 72-hour landmarks
Same measurement as the primary outcome, estimated separately at the 48-hour and 72-hour landmarks with 95% confidence intervals
Calibration slope (dimensionless) of the landmark model at the 24-, 48- and 72-hour landmarks
Slope obtained by logistic regression of the observed outcome on the logit of the predicted risk; a value of 1 indicates perfect calibration, below 1 indicates over-fitting and above 1 under-fitting.
Brier score (range 0 to 1) of the landmark model at the 24-, 48- and 72-hour landmarks
Mean squared difference between predicted risk and observed outcome, where lower values indicate better overall performance.
Difference in area under the receiver operating characteristic curve (range -1 to 1) between the landmark model and the centre-recorded APACHE II score
Paired difference in discrimination, computed as model area under the curve minus APACHE II area under the curve on the same patients, with 95% confidence interval; negative values indicate the model discriminates worse than APACHE II
Sponsors and contacts
Click on the lead sponsor to view all of their trials.
Fujian Provincial Hospital
Lead sponsor
Fuzhou University
Collaborator
Second Affiliated Hospital of Fujian Medical University
Collaborator
Hui'an County Hospital
Collaborator
Zhangzhou Affiliated Hospital of Fujian Medical University
Collaborator
Shishi General Hospital
Collaborator
This trial is not recruiting at the moment. You can still explore other options: