About this trial
Monitoring pulmonary perfusion is crucial in critical care, especially for conditions like ARDS. Electrical Impedance Tomography (EIT) is a valuable, non-invasive tool for real-time bedside monitoring.While well-established for lung ventilation, EIT faces a challenge in perfusion imaging because the related impedance signal is very weak. Currently, two main methods are used:Saline Bolus EIT: Involves injecting a saline solution during a breath-hold to track blood flow.Pulse Wave EIT: Utilizes cardiac-induced vascular pulsations to assess perfusion.However, both methods have limitations in ARDS patients, as the disease's altered physiology can affect their accuracy.
This study compares pulse wave versus saline bolus EIT for pulmonary perfusion assessment in ARDS patients and investigates the impact of different PEEP levels.
Eligibility criteria
This trial does not accept healthy volunteersQualifiers
Age: 18-80 years;
Endotracheal intubation and mechanical ventilation;
Presence of a subclavian or internal jugular venous catheter in place;
Diagnosis of ARDS according to the 2023 global ARDS definition.
Disqualifiers
Age <18 or >80 years;
Severe obesity (BMI ≥35 kg/m²);
Pregnant or lactating women;
Pulmonary diseases: acute asthma exacerbation, COPD, pulmonary fibrosis, pleural effusion, pneumothorax, or pulmonary embolism;
Trial population
Patients who meet the inclusion and exclusion criteria will undergo both pulse wave and saline bolus EIT monitoring at PEEP levels of 5 and 15 cmH₂O.
Trial design
Cohort
Prospective
Treatments tested in this trial
Not listed
Trial groups
Trial outcomes
Primary outcomes
Pulmonary perfusion was assessed using both pulse wave and saline bolus EIT at PEEP levels of 5 and 15 cmH₂O.
At a PEEP of 5 cmH₂O, pulse wave EIT data were recorded for 3 minutes. Subsequently, during an inspiratory or expiratory hold, a 10 mL bolus of 10% hypertonic saline was administered via the central venous catheter while EIT data were simultaneously recorded for another 3 minutes. This procedure was repeated at a PEEP of 15 cmH₂O. Pulmonary perfusion data were obtained through offline analysis of the EIT data.
Secondary outcomes
At PEEP 5 cmH₂O and 15 cmH₂O, perform EIT monitoring of pulmonary perfusion during a 15-second inspiratory or expiratory hold.
At a PEEP of 5 cmH₂O, EIT data were first recorded for 1 minute, followed by a 15-second inspiratory hold, after which data acquisition was continued for an additional 2 minutes. The entire procedure was repeated at a PEEP of 15 cmH₂O. Pulmonary perfusion data were subsequently analyzed using offline software.
Under PEEP 5 cmH₂O conditions, EIT data were acquired during bolus injections of either 10 mL of 0.9% saline or 10 mL of 10% hypertonic saline for pulmonary perfusion analysis.
At a PEEP of 5 cmH₂O, the following protocol was performed: First, EIT data were recorded for 1 minute, followed by a bolus injection of 10 mL of 0.9% saline via the central venous catheter; data acquisition then continued for an additional 2 minutes. Then, the procedure was repeated with a bolus injection of 10 mL of 10% hypertonic saline. Pulmonary perfusion data were subsequently analyzed using offline software.
The ventilation-perfusion matching percentage was assessed using both pulse wave and saline bolus EIT at PEEP levels of 5 and 15 cmH₂O.
The ventilation-perfusion matching percentage was derived from EIT images using offline analysis software.
The ventilation-perfusion matching percentage was monitored by EIT during 15-second inspiratory or expiratory holds at PEEP levels of 5 and 15 cmH₂O.
The ventilation-perfusion matching percentage was derived from EIT images using offline analysis software.
Sponsors and contacts
Click on the lead sponsor to view all of their trials.