Pulse Wave vs. Saline Contrast EIT for Pulmonary Perfusion in ARDS

Trial statusRecruiting
Trial phaseNot listed
Trial typeObservational
Biological sexAll
Age18-80
SponsorUnion Hospital, Tongji Medical College, Huazhong University of Science and Technology

About this trial

Monitoring pulmonary perfusion is crucial in critical care, especially for conditions like ARDS. Electrical Impedance Tomography (EIT) is a valuable, non-invasive tool for real-time bedside monitoring.While well-established for lung ventilation, EIT faces a challenge in perfusion imaging because the related impedance signal is very weak. Currently, two main methods are used:Saline Bolus EIT: Involves injecting a saline solution during a breath-hold to track blood flow.Pulse Wave EIT: Utilizes cardiac-induced vascular pulsations to assess perfusion.However, both methods have limitations in ARDS patients, as the disease's altered physiology can affect their accuracy.

This study compares pulse wave versus saline bolus EIT for pulmonary perfusion assessment in ARDS patients and investigates the impact of different PEEP levels.

Eligibility criteria

This trial does not accept healthy volunteers

Qualifiers

Age: 18-80 years;

Endotracheal intubation and mechanical ventilation;

Presence of a subclavian or internal jugular venous catheter in place;

Diagnosis of ARDS according to the 2023 global ARDS definition.

Disqualifiers

Age <18 or >80 years;

Severe obesity (BMI ≥35 kg/m²);

Pregnant or lactating women;

Pulmonary diseases: acute asthma exacerbation, COPD, pulmonary fibrosis, pleural effusion, pneumothorax, or pulmonary embolism;

Trial population

Patients who meet the inclusion and exclusion criteria will undergo both pulse wave and saline bolus EIT monitoring at PEEP levels of 5 and 15 cmH₂O.

Trial design

Design model

Cohort

Time perspective

Prospective

Treatments tested in this trial

Not listed

Trial groups

No trial groups listed

Trial outcomes

Primary outcomes

1

Pulmonary perfusion was assessed using both pulse wave and saline bolus EIT at PEEP levels of 5 and 15 cmH₂O.

At a PEEP of 5 cmH₂O, pulse wave EIT data were recorded for 3 minutes. Subsequently, during an inspiratory or expiratory hold, a 10 mL bolus of 10% hypertonic saline was administered via the central venous catheter while EIT data were simultaneously recorded for another 3 minutes. This procedure was repeated at a PEEP of 15 cmH₂O. Pulmonary perfusion data were obtained through offline analysis of the EIT data.

Time frame
Under both PEEP 5 cmH₂O and PEEP 15 cmH₂O conditions, EIT data were acquired after 30 minutes of stable ventilation.

Secondary outcomes

1

At PEEP 5 cmH₂O and 15 cmH₂O, perform EIT monitoring of pulmonary perfusion during a 15-second inspiratory or expiratory hold.

At a PEEP of 5 cmH₂O, EIT data were first recorded for 1 minute, followed by a 15-second inspiratory hold, after which data acquisition was continued for an additional 2 minutes. The entire procedure was repeated at a PEEP of 15 cmH₂O. Pulmonary perfusion data were subsequently analyzed using offline software.

Time frame
Under both PEEP 5 cmH₂O and PEEP 15 cmH₂O conditions, EIT data were acquired after 30 minutes of stable ventilation.
2

Under PEEP 5 cmH₂O conditions, EIT data were acquired during bolus injections of either 10 mL of 0.9% saline or 10 mL of 10% hypertonic saline for pulmonary perfusion analysis.

At a PEEP of 5 cmH₂O, the following protocol was performed: First, EIT data were recorded for 1 minute, followed by a bolus injection of 10 mL of 0.9% saline via the central venous catheter; data acquisition then continued for an additional 2 minutes. Then, the procedure was repeated with a bolus injection of 10 mL of 10% hypertonic saline. Pulmonary perfusion data were subsequently analyzed using offline software.

Time frame
Under a PEEP of 5 cmH₂O, EIT data acquisition was performed after 30 minutes of stable ventilation.
3

The ventilation-perfusion matching percentage was assessed using both pulse wave and saline bolus EIT at PEEP levels of 5 and 15 cmH₂O.

The ventilation-perfusion matching percentage was derived from EIT images using offline analysis software.

Time frame
Under both PEEP 5 cmH₂O and PEEP 15 cmH₂O conditions, EIT data were acquired after 30 minutes of stable ventilation.
4

The ventilation-perfusion matching percentage was monitored by EIT during 15-second inspiratory or expiratory holds at PEEP levels of 5 and 15 cmH₂O.

The ventilation-perfusion matching percentage was derived from EIT images using offline analysis software.

Time frame
Under both PEEP 5 cmH₂O and PEEP 15 cmH₂O conditions, EIT data were acquired after 30 minutes of stable ventilation.

Other outcomes

Sponsors and contacts