Radiographic Stability of Hip Prosthesis Prior to Revision Surgery

Trial statusNot yet recruiting
Trial phaseNot listed
Trial typeObservational
Biological sexAll
AgeNot listed
SponsorGeorgios Tsikandylakis, MD PhD

About this trial

The goal of this validation study is to compare the preoperative implant stability, assessed by Implant Movement Analysis (IMA), provocation dual CT scans, with the intraoperative stability evaluation in revision hip arthoplasty. The main question it aims to answer is:

Does IMA reflect the intraoperative clinical evaluation of implant stability? Participants scheduled for revision hip arthoplasty will undergo IMA preoperativelly in addition to rutine clinical work up. During revision arthoplasty, a surgeon blinded to the IMA results will assess clinically the stability of the hip prosthesis. IMA will be compared with the intraoperative findings to assess IMAs sensitivity and specificity

Eligibility criteria

This trial does not accept healthy volunteers

Qualifiers

Patient scheduled for revision THA due to aseptic loosening.

One component (cup or stem) has no convincing loosening signs, based on the preoperative plain radiographs and clinical assessment by the attending surgeon.

Radiographs not older than 8 weeks prior to surgery.

Disqualifiers

Both cup and stem have been preoperatively evaluated as loose

Instability with repeating dislocation of the THA

Non-aseptic revision surgery, based on preoperative work up.

The scheduled revisionsurgery is cancelled.

Trial population

Patients with a painful total hip arthoplasty that are scheduled for revision hip arthoplasty due to suspected prosthesis loosening. At least one implant component (either cup or stem) should not have any obvious signs of loosening. Only the implant component with no obvious signs of loosening will be included in the study.

Trial design

Design model

Cohort

Time perspective

Cross-sectional

Treatments tested in this trial

  • Implant motion provocation CT

    Diagnostic test

    Implant Movement Analysis. A low dose CT scan is performed with the hip fixed in external rotation. Then another low dose CT scan is performed with the hip fixed in internal rotation.The CT scans are then overimposed to each other and implant motion in relation to host bone is visualized,

Treatment groups

600 Participants
are divided into 1 treatment group
Group A: Study group1 intervention

Trial outcomes

Primary outcomes

1

Cup and stem stability

The stability of the cup and the stem is evaluated: 1. Preoperatively with IMA as binary outcome (loose/not loose). 2. Intraoperatively by the surgeon as binary outcome (loose/notloose).

Time frame
within 2 months month

Secondary outcomes

Other outcomes