This study evaluates two different control strategies for a rehabilitation device that combines recumbent leg-cycling with functional electrical stimulation (FES) of the quadriceps muscle. The device assists pedaling using a motor and electrical stimulation, and is intended for use after knee surgery (such as ACL reconstruction) or in other lower-limb rehabilitation. During muscle stimulation, fatigue can develop, which reduces the force produced by the stimulated muscle. This study compares a standard control strategy with a new strategy that adjusts stimulation based on the muscle's fatigue level, measured in real time. Healthy adult volunteers will complete two sessions on a recumbent stationary bicycle, 2 to 7 days apart. Each session lasts about 60 minutes and includes periods of pedaling with electrical stimulation, as well as isometric wall squats to induce muscle fatigue. Muscle activity, pedal force, and pedal position will be recorded throughout. The goal is to determine which control strategy produces more mechanical work from the leg muscles and better tracks the desired pedaling pattern, especially as fatigue develops.

Eligibility criteria

This trial accepts healthy volunteers

Qualifiers

Age between 18 and 60 years.

Body weight less than 120 kg.

No injuries or conditions affecting the osteoarticular or musculoskeletal system.

No strenuous physical exertion of the lower limb within the previous 24 hours.

Disqualifiers

Pregnancy.

History of chronic pain, neuromuscular disorders, or lower-limb surgical interventions without medical clearance.

Use of analgesics within 24 hours prior to participation.

Lack of cooperation.

Trial design

Design model

Crossover

Treatments tested in this trial

  • Fatigue-Feedback FES Control Strategy

    Device

    A closed-loop control strategy for the FES-assisted recumbent cycling device that explicitly incorporates real-time estimation of muscle fatigue (based on pedal force variation and M-wave median frequency) into the calculation of motor and electrical stimulation control signals.

  • Standard FES Control Strategy

    Device

    A closed-loop control strategy for the FES-assisted recumbent cycling device based on a previously published approach, without explicit real-time incorporation of muscle fatigue estimation into the control signal calculation.

Treatment groups

30 Participants
are divided into 2 treatment groups
Group A: Fatigue-Feedback Control FirstExperimental treatment 2 interventions
Group B: Standard Control FirstActive comparator 2 interventions

Trial outcomes

Primary outcomes

1

Mechanical work performed during FES-assisted pedaling

Mechanical work performed by the stimulated lower limb during FES-assisted pedaling, in joules. Computed from pedal force (load cells) and pedal angular position, integrated over the stimulated regions of the pedaling cycle. Measured during the FES pedaling blocks before and after the isometric fatigue-induction phase, and compared between control strategies within each participant.

Time frame
Day 1 (Session 1) and Day 3 to Day 8 (Session 2)

Secondary outcomes

1

Pedal force

Force applied to the pedals, in newtons, recorded with compression load cells mounted on the pedal platforms during the FES pedaling blocks before and after the isometric fatigue-induction phase.

Time frame
Day 1 (Session 1) and Day 3 to Day 8 (Session 2)
2

Muscle electrical activity (EMG RMS)

Muscle electrical activity quantified as the root mean square (RMS) value computed from the surface electromyography signal of the stimulated and contralateral muscles.

Time frame
Day 1 (Session 1) and Day 3 to Day 8 (Session 2)
3

Muscle fatigue

Muscle fatigue estimated from the variation in pedal force and from the shift in median frequency of the M-wave obtained from the surface electromyography signal.

Time frame
Day 1 (Session 1) and Day 3 to Day 8 (Session 2), before and after the isometric fatigue-induction phase
4

Cadence tracking error

Error between the target pedaling cadence reference and the cadence actually achieved during FES-assisted pedaling.

Time frame
Day 1 (Session 1) and Day 3 to Day 8 (Session 2)