About this trial
This prospective observational study aims to investigate the influence of Body Mass Index (BMI) percentiles on internal arterial dimensions and skin-to-artery depth of bilateral radial and ulnar arteries in pediatric patients aged 0 to 18 years undergoing elective surgery under general anesthesia. Preoperative arterial catheterization in children is technically challenging due to small vessel calibers and high vasospasm risk. Using high-resolution ultrasound with a high-frequency hockey stick probe (6.0-15.0 MHz, LS6-15, SAMSUNG HM70 EVO) and an acoustic gel pad floating technique under standardized general anesthesia, researchers will measure internal anteroposterior (AP), transverse (TR), and geometric corrected diameters (Dc) as well as depth bilaterally at the wrist. Arterial dimensions will be compared across four BMI percentile cohorts (underweight, normal weight, overweight, obese) and correlated with standard pediatric cannula calibers (24-G, 22-G, 20-G) to evaluate vessel-catheter ratios and potential lumen occupation percentages.
Furthermore, anthropometric and sonographic variables will be integrated into regression models to explore a predictive equation/algorithm for optimal pediatric cannula size selection.
Eligibility criteria
This trial does not accept healthy volunteersQualifiers
Age 0 to 18 years (0 to 216 months), including neonates, infants, young children, school-age children, and adolescents
Scheduled for elective surgical procedures under general anesthesia
American Society of Anesthesiologists (ASA) physical status score I, II, or III
Written informed consent obtained from parents or legal guardians
Disqualifiers
Emergency surgical procedures
ASA physical status score IV or higher with severe hemodynamic instability
Known peripheral vascular disease, Raynaud's phenomenon, vasculitis, or congenital upper extremity vascular/orthopedic malformations
History of prior trauma, vascular surgery, or major orthopedic surgery on the upper extremities
Trial population
Pediatric patients aged 0 to 18 years classified as ASA I, II, or III scheduled to undergo elective surgical procedures under general anesthesia at Ankara Etlik City Hospital, Children's Hospital.
Trial design
Cohort
Prospective
Treatments tested in this trial
Not listed
Trial groups
Trial outcomes
Primary outcomes
Bilateral Radial Artery Internal Diameters
Internal anteroposterior (AP), transverse (TR), and corrected diameter \[Dc = sqrt(AP \* TR)\] of the radial artery measured bilaterally in millimeters using a single transverse acoustic window at the distal wrist crease with high-resolution ultrasound (6.0-15.0 MHz) and zero-compression acoustic gel pad technique under standardized general anesthesia.
Bilateral Ulnar Artery Internal Diameters
Internal anteroposterior (AP), transverse (TR), and corrected diameter \[Dc = sqrt(AP \* TR)\] of the ulnar artery measured bilaterally in millimeters at the same transverse acoustic window level as the radial artery, immediately proximal to Guyon's canal, under standardized general anesthesia.
Secondary outcomes
Skin-to-Artery Depth of Radial and Ulnar Arteries
Perpendicular distance from the superficial epidermal skin surface to the anterior intimal vessel wall of bilateral radial and ulnar arteries (in millimeters) measured via ultrasound using the zero-compression acoustic gel standoff technique.
Radial versus Ulnar Caliber Ratio and Bilateral Anatomical Symmetry
Ratio of corrected internal diameters between radial and ulnar arteries within the same extremity (Dc-radial / Dc-ulnar ratio), as well as side-to-side bilateral symmetry between right and left arms across BMI percentile groups.
Vessel-to-Catheter Ratio (VCR) and Predicted Lumen Occupation Percentage (%LO)
Mathematical calculation of vessel-to-catheter diameter ratio (VCR = Arterial Dc / Catheter OD) and cross-sectional lumen occupation percentage (%LO = ((Catheter OD / Arterial Dc)\^2) x 100) based on measured arterial diameters versus standard pediatric cannula sizes (24-G \[OD: 0.7 mm\], 22-G \[OD: 0.9 mm\], 20-G \[OD: 1.1 mm\]). Proportions meeting safety thresholds (VCR \>= 2.5, and %LO \<= 33% and \<= 45%) will be analyzed across BMI percentile categories.
Development of a Predictive Model for Pediatric Cannula Size Selection
Multivariable linear and logistic regression models and ROC curve analyses combining anthropometric parameters (age, weight, height, BMI percentiles) and ultrasonographic vessel dimensions to establish a predictive equation and clinical decision algorithm for optimal cannula gauge selection (20-G, 22-G, 24-G), minimizing vessel-catheter mismatch.
Sponsors and contacts
Click on the lead sponsor to view all of their trials.
This trial is not recruiting at the moment. You can still explore other options: