Relationship Between Body Mass Index Percentiles and Radial and Ulnar Artery Diameters in Pediatric Patients

Trial statusNot yet recruiting
Trial phaseNot listed
Trial typeObservational
Biological sexAll
Age0-18
SponsorAnkara Etlik City Hospital

About this trial

This prospective observational study aims to investigate the influence of Body Mass Index (BMI) percentiles on internal arterial dimensions and skin-to-artery depth of bilateral radial and ulnar arteries in pediatric patients aged 0 to 18 years undergoing elective surgery under general anesthesia. Preoperative arterial catheterization in children is technically challenging due to small vessel calibers and high vasospasm risk. Using high-resolution ultrasound with a high-frequency hockey stick probe (6.0-15.0 MHz, LS6-15, SAMSUNG HM70 EVO) and an acoustic gel pad floating technique under standardized general anesthesia, researchers will measure internal anteroposterior (AP), transverse (TR), and geometric corrected diameters (Dc) as well as depth bilaterally at the wrist. Arterial dimensions will be compared across four BMI percentile cohorts (underweight, normal weight, overweight, obese) and correlated with standard pediatric cannula calibers (24-G, 22-G, 20-G) to evaluate vessel-catheter ratios and potential lumen occupation percentages.

Furthermore, anthropometric and sonographic variables will be integrated into regression models to explore a predictive equation/algorithm for optimal pediatric cannula size selection.

Eligibility criteria

This trial does not accept healthy volunteers

Qualifiers

Age 0 to 18 years (0 to 216 months), including neonates, infants, young children, school-age children, and adolescents

Scheduled for elective surgical procedures under general anesthesia

American Society of Anesthesiologists (ASA) physical status score I, II, or III

Written informed consent obtained from parents or legal guardians

Disqualifiers

Emergency surgical procedures

ASA physical status score IV or higher with severe hemodynamic instability

Known peripheral vascular disease, Raynaud's phenomenon, vasculitis, or congenital upper extremity vascular/orthopedic malformations

History of prior trauma, vascular surgery, or major orthopedic surgery on the upper extremities

Trial population

Pediatric patients aged 0 to 18 years classified as ASA I, II, or III scheduled to undergo elective surgical procedures under general anesthesia at Ankara Etlik City Hospital, Children's Hospital.

Trial design

Design model

Cohort

Time perspective

Prospective

Treatments tested in this trial

Not listed

Trial groups

200 Participants
are grouped into 4 trial groups
Group A: Group 1: Underweight (<5th Percentile)
Group B: Group 2: Normal Weight (5th-84th Percentile)
Group C: Group 3: Overweight (85th-94th Percentile)
Group D: Group 4: Obese (≥95th Percentile)

Trial outcomes

Primary outcomes

1

Bilateral Radial Artery Internal Diameters

Internal anteroposterior (AP), transverse (TR), and corrected diameter \[Dc = sqrt(AP \* TR)\] of the radial artery measured bilaterally in millimeters using a single transverse acoustic window at the distal wrist crease with high-resolution ultrasound (6.0-15.0 MHz) and zero-compression acoustic gel pad technique under standardized general anesthesia.

Time frame
Intraoperatively on the day of surgery, immediately following anesthesia induction once hemodynamic stability is achieved.
2

Bilateral Ulnar Artery Internal Diameters

Internal anteroposterior (AP), transverse (TR), and corrected diameter \[Dc = sqrt(AP \* TR)\] of the ulnar artery measured bilaterally in millimeters at the same transverse acoustic window level as the radial artery, immediately proximal to Guyon's canal, under standardized general anesthesia.

Time frame
Intraoperatively on the day of surgery, immediately following anesthesia induction once hemodynamic stability is achieved.

Secondary outcomes

1

Skin-to-Artery Depth of Radial and Ulnar Arteries

Perpendicular distance from the superficial epidermal skin surface to the anterior intimal vessel wall of bilateral radial and ulnar arteries (in millimeters) measured via ultrasound using the zero-compression acoustic gel standoff technique.

Time frame
Intraoperatively on the day of surgery.
2

Radial versus Ulnar Caliber Ratio and Bilateral Anatomical Symmetry

Ratio of corrected internal diameters between radial and ulnar arteries within the same extremity (Dc-radial / Dc-ulnar ratio), as well as side-to-side bilateral symmetry between right and left arms across BMI percentile groups.

Time frame
Intraoperatively on the day of surgery.
3

Vessel-to-Catheter Ratio (VCR) and Predicted Lumen Occupation Percentage (%LO)

Mathematical calculation of vessel-to-catheter diameter ratio (VCR = Arterial Dc / Catheter OD) and cross-sectional lumen occupation percentage (%LO = ((Catheter OD / Arterial Dc)\^2) x 100) based on measured arterial diameters versus standard pediatric cannula sizes (24-G \[OD: 0.7 mm\], 22-G \[OD: 0.9 mm\], 20-G \[OD: 1.1 mm\]). Proportions meeting safety thresholds (VCR \>= 2.5, and %LO \<= 33% and \<= 45%) will be analyzed across BMI percentile categories.

Time frame
Intraoperatively on the day of surgery.
4

Development of a Predictive Model for Pediatric Cannula Size Selection

Multivariable linear and logistic regression models and ROC curve analyses combining anthropometric parameters (age, weight, height, BMI percentiles) and ultrasonographic vessel dimensions to establish a predictive equation and clinical decision algorithm for optimal cannula gauge selection (20-G, 22-G, 24-G), minimizing vessel-catheter mismatch.

Time frame
Intraoperatively on the day of surgery

Other outcomes

Sponsors and contacts

Click on the lead sponsor to view all of their trials.

This trial is not recruiting at the moment. You can still explore other options: