Restoration of Central Vision With PRIMA in Patients With Photoreceptor Degeneration

Trial statusRecruiting
Trial phaseNot applicable
Trial typeInterventional
Biological sexAll
Age18+
SponsorScience Corporation

About this trial

The objective of this study is to evaluate the efficacy and safety of the PRIMA Products in participants with inherited retinal degeneration affecting the macula (including but not limited to Stargardt disease, and Retinitis Pigmentosa).

Eligible participants will be implanted with the PRIMA Stim implant. The participants will be assessed with various visual function and functional vision tests at defined timepoints throughout the clinical investigation with the PRIMA Products. The purpose of this study is to gather enough clinical data to support the clinical evaluation required for the continuous development to improve the PRIMA Products.

Eligibility criteria

This trial does not accept healthy volunteers

Qualifiers

Is 18 years or older at the date of inclusion;

Has a confirmed diagnosis of inherited retinal degeneration with the macula affected in both eyes;

The study eye has best corrected visual acuity of logMAR 1.2 (20/320) or worse as measured by ETDRS test;

Has an atrophic patch in the study eye including the fovea of at least the implant size (>4.5 mm2 and >2.4 mm in minimum diameter);

Disqualifiers

1. Has cataract in the study eye (with LOCS III scale NO, NC, C or P>1); (these patients will need to have cataract surgery performed prior to completion of baseline testing; all other patients will get IOL replacement during the PRIMA Stim implantation);

Underwent intraocular lens implantation in the study eye within the last month prior to enrolment (this corresponds to 4 weeks or 28 days) ;

Has an implanted IOL in the study eye and a refraction of the study eye outside of -4D; +4D limit (this criterion is not relevant for phakic eyes)

Has a highly myopic study eye (>26 mm AP);

Trial design

Design model

Single group

Treatments tested in this trial

  • PRIMA Products

    Device

    Implantation of PRIMA, Vision training, follow up

Treatment groups

5 Participants
are divided into 1 treatment group
Group A: PRIMA ProductsExperimental treatment 1 intervention

Trial outcomes

Primary outcomes

1

Proportion of participants with an improvement of visual acuity

Proportion of participants with an improvement of visual acuity of logMAR 0.2 or more

Time frame
12 months
2

Number and severity of device and procedure related serious adverse events

Number and severity of device and procedure related serious adverse events

Time frame
12 months

Secondary outcomes

1

Proportion of participants with an improvement of visual acuity

Proportion of participants with an improvement of visual acuity of logMAR 0.2 or more

Time frame
6, 24 and 36 months
2

Mean improvement in visual acuity

Mean improvement in visual acuity measured by ETDRS (extended by the Berkeley Rudimentary Vision Test)

Time frame
6, 12, 24 and 36 months
3

Mean improvement in the reading test

Mean improvement in reading acuity, measured using the Radner Reading Charts and reported on the logRAD (Reading Acuity Determination) scale. The logRAD scale ranges from 1.2 logRAD (worst reading acuity) to -0.2 logRAD (best reading acuity) at 40 cm. Lower logRAD values indicate better reading acuity.

Time frame
12, 24 and 36 months
4

Number and severity of procedure and device related adverse events throughout the study

Number and severity of procedure and device related adverse events throughout the study

Time frame
up to 36 months