Right Ventricular Function Changes After CIED Implantation: The RIGHT-CIED Study

Trial statusRecruiting
Trial phaseNot listed
Trial typeObservational
Biological sexAll
Age18+
SponsorIstanbul University - Cerrahpasa

About this trial

This study aims to understand how the right side of the heart changes in people who receive an implantable cardiac electronic device (CIED), such as a pacemaker, ICD, or CRT device. The right ventricle (RV) can sometimes be affected after these devices are placed, but the reasons and timing are not well understood.

To investigate this, we will examine participants at two time-points: before their device is implanted and again six months later. At each visit, we will assess heart function using echocardiography, a non-contrast cardiac MRI scan, and an ultrasound score of venous congestion called the VEXUS score. We will also take a small blood sample to measure a biomarker called FGF-23, which may reflect changes in heart function.

The study does not involve any experimental treatment, and all implanted devices are part of routine medical care. The imaging tests and blood samples are for research purposes only. By comparing the measurements before and after device implantation, we hope to better understand how CIEDs influence right-sided heart function and whether imaging findings are related to changes in blood biomarkers.

Eligibility criteria

This trial does not accept healthy volunteers

Qualifiers

Adults aged 18 years or older.

Scheduled to undergo implantation of a clinically indicated pacemaker, ICD, or CRT device.

Able to undergo transthoracic echocardiography, VEXUS ultrasound assessment, and non-contrast cardiac MRI.

Able to provide written informed consent.

Disqualifiers

Contraindication to cardiac MRI (e.g., severe claustrophobia or MRI-unsafe implanted material).

Inability to undergo echocardiography or ultrasound assessment.

Known pulmonary arterial hypertension (Group 1 PH).

Significant congenital heart disease.

Trial population

Participants will be recruited from the cardiology clinics and electrophysiology unit of Istanbul University-Cerrahpaşa Cardiology Institute. The study population consists of adult patients scheduled for implantation of a clinically indicated pacemaker, ICD, or CRT device. All participants represent a routine tertiary-care population referred for device therapy due to bradyarrhythmia, heart failure, or ventricular arrhythmia indications.

Trial design

Design model

Cohort

Time perspective

Prospective

Treatments tested in this trial

  • Multimodal Right Ventricular Evaluation

    Other intervention

    Non-invasive assessments including transthoracic echocardiography, VEXUS ultrasound scoring, non-contrast cardiac MRI using 1.5T scanner, and venous blood sampling for EDTA plasma biomarker analysis (FGF-23 and BNP). These procedures are for research measurements only and do not alter or replace routine clinical care. No therapeutic intervention or assignment is performed.

Treatment groups

40 Participants
are divided into 1 treatment group
Group A: CIED Implantation Cohort1 intervention

Trial outcomes

Primary outcomes

1

Change in Right Ventricular Ejection Fraction (RVEF) by Cardiac MRI

RVEF will be quantified using non-contrast 1.5T cardiac MRI cine imaging. The primary endpoint is the absolute change in RVEF between pre-implantation and 6-month follow-up.

Time frame
Baseline (pre-implantation) to 6 months post-implantation
2

Change in Tricuspid Regurgitation Severity

Tricuspid regurgitation will be graded (none, mild, moderate, severe) using echocardiography and confirmed by CMR-derived regurgitant volume.

Time frame
Baseline to 6 months

Secondary outcomes

1

Change in Right Ventricular End-Diastolic Volume (RVEDV) by Cardiac MRI

RVEDV will be measured from short-axis cine stacks. The endpoint is the change in volume between baseline and 6 months.

Time frame
Baseline to 6 months
2

Change in VEXUS Score

VEXUS venous congestion score (IVC, hepatic vein Doppler, portal vein pulsatility, renal vein Doppler) will be calculated at each visit.

Time frame
Baseline to 6 months
3

Change in Right Ventricular Longitudinal Strain (RV-FWLS)

Measured via speckle-tracking echocardiography.

Time frame
Baseline to 6 months
4

Change in Plasma FGF-23 Concentration

EDTA plasma FGF-23 will be measured via ELISA. The endpoint is the change in concentration from baseline to 6 months.

Time frame
Baseline to 6 months