Rotator Cuff Tendon Repair With FiberLocker System Patch Augmentation

Trial statusRecruiting
Trial phaseNot applicable
Trial typeInterventional
Biological sexAll
Age40-65
SponsorZuriMED Technologies AG

About this trial

The overall objective of this clinical investigation is to assess the safety and efficacy of full-thickness arthroscopic rotator cuff repairs augmented with the FiberLocker System for the subjects. The primary outcome of the investigation is to assess the safety after full-thickness arthroscopic rotator cuff repairs augmented with the FiberLocker System in terms of postoperative adverse events through the 12-month follow-up. Main secondary outcomes include measures of efficacy and clinical performance evaluated at 6-week, 4.5-month, and 12-month follow-ups including retear rate assessed using MRI and different functional performance scores.

Eligibility criteria

This trial does not accept healthy volunteers

Qualifiers

Subject requires surgical treatment of a full-thickness rotator cuff tear, according to Balgrist standard procedure

Full-thickness tear of the supraspinatus or combined infraspinatus and supraspinatus

The rotator cuff tear is of traumatic origin.

Subject is ≥ 40 years of age & ≤ 65 years of age.

Disqualifiers

Vulnerable subjects (as defined in ISO 14155)

Subjects who do not have the power of judgement or are unable to fully understand all aspects of the investigation that are relevant to the decision to participate

Participation in another investigation with an investigational drug or another MD within the 30 days preceding and during the present investigation,

Previous enrolment into the current investigation,

Trial design

Design model

Single group

Treatments tested in this trial

  • FiberLocker® System (encompassing SpeedPatch® PET and FiberLocker Instrument® SN)

    Device

    The FiberLocker® System is a mechanical augmentation system that includes an implant (SpeedPatch® PET) and an instrument (FiberLocker® Instrument SN) for its attachment. The implant is composed of non-woven PET fibers, and the instrument features a reciprocating needle at its tip, which pushes the individual patch fibers into the underlying tendon tissue

Treatment groups

50 Participants
are divided into 1 treatment group
Group A: Augmentation of Rotator Cuff Repair using the FiberLocker SystemExperimental treatment 1 intervention

Trial outcomes

Primary outcomes

1

Total Number of Adverse Events (AEs)

All operative and postoperative AEs will be recorded. Safety outcomes will be determined by evaluating the type, frequency, seriousness, and relationship to device or procedure of AEs for all subjects.

Time frame
Surgery to 12-month follow-up
2

Total Number of Serious Adverse Events (SAEs)

All operative and postoperative SAEs will be recorded. Safety outcomes will be determined by evaluating the type, frequency, and relationship to device or procedure of SAEs for all subjects.

Time frame
Surgery to 12-month follow-up
3

Number of AE related to Device

The operative and postoperative AEs that are related to the device will be reported. Safety outcomes will be determined by evaluating the type and frequency for all subjects.

Time frame
Surgery to 12-month follow-up
4

Number of SAE related to Device

The operative and postoperative SAEs that are related to the device will be reported. Safety outcomes will be determined by evaluating the type and frequency for all subjects.

Time frame
Surgery to 12-month follow-up

Secondary outcomes

1

Retear Rate

Retears are defined as repairs showing structural defect of the tendon bone-interface on MRI according to type IV or V of the Sugaya classification. Cuff integrity according to the Sugaya classification is defined as follows: type I (repaired cuff of sufficientthickness, homogeneously low signal intensity), type II (sufficient thickness, partial high-signal intensity area), type III (insufficient thickness without discontinuity), type IV (minor discontinuity in 1 section, suggestive of a small tear), type V (major discontinuity in each image, suggestive of a medium-to-large tear).

Time frame
6-week, 4.5-month and 12-month follow-up
2

Constant-Murley Score

The Constant score will be calculated in a 100-point scale and compared with baseline. It will be measured with a patient-reported questionnaire \& medical professional assessment at baseline and 12-month follow-up visit. A higher score indicates better function.

Time frame
Baseline and 12-month follow-up
3

Visual Analog Scale for Pain (VAS)

The VAS score will be calculated in a 0 to 10 scale and compared with baseline. Thereby, a higher score indicates greater pain intensity. VAS for average pain score over the last 24 hours will be assessed with a questionnaire.

Time frame
Baseline, 2-week, 4.5-month and 12-month follow-up
4

Subjective Shoulder Value (SSV) Score

The SSV score is a patient-reported outcome measure used to assess a patient's perception of their shoulder function. It consists of a single question and each subject has to rate their shoulder function on a scale from 0% to 100%. Thereby, higher percentages indicates better shoulder function.

Time frame
Baseline, 4.5-month and 12-month follow-up

Other outcomes

Sponsors and contacts

Click on the lead sponsor to view all of their trials.