About this trial
This prospective, multicenter, post-market observational study aims to evaluate the safety and effectiveness of the crystalline sirolimus-coated balloon (SeQuent® Sirolimus-Coated Balloon) for the treatment of coronary artery disease in routine clinical practice. Consecutive, unselected adult patients undergoing percutaneous coronary intervention for de novo coronary lesions or in-stent restenosis will be enrolled.
The primary objective is to assess target lesion failure at 12 months, defined as the composite of target vessel myocardial infarction or ischemia-driven target lesion revascularization. Secondary objectives include angiographic procedural success, major adverse cardiovascular events, bleeding outcomes, and longer-term clinical results up to 36 months, as well as outcomes across predefined anatomical and clinical subgroups.
The study seeks to answer whether treatment with the crystalline sirolimus-coated balloon provides a safe and effective revascularization strategy in a real-world population with diverse clinical presentations and lesion characteristics.
Eligibility criteria
This trial does not accept healthy volunteersQualifiers
All patients must provide written informed consent.
Patients aged ≥18 years with coronary artery disease in whom, at the operator's discretion, treatment of a coronary stenosis in a native vessel (either de novo lesion or in-stent restenosis) or in a coronary bypass graft using the cSCB is indicated, in accordance with routine clinical practice.
All treated lesions/segments (single or tandem) must receive cSCB therapy covering at least 3 mm beyond both edges of the lesion or pre-dilated segment to avoid geographic miss.
In patients with multivessel coronary artery disease, all non-target vessels will be treated according to operator discretion: a) If more than one vessel is treated with the investigational device (SeQuent® SCB), all vessels will be documented and analyzed separately. b) Only one lesion per vessel will be included unless lesions are separated by ≥20 mm. c) Only one lesion per vessel will be included. d) If more than one lesion in the target vessel requires treatment, all lesions treated with a device different from the investigational procedure or with a device other than the investigational device (SeQuent® SCB) must be separated from the target lesion by ≥20 mm or considered as a single treated lesion according to this study protocol.
Disqualifiers
Explicit refusal by the patient to participate in the study.
Known intolerance to sirolimus or to any component of the investigational device.
Contraindication to any antiplatelet therapy.
Life expectancy less than 12 months.
Trial population
Adult patients (≥18 years) with coronary artery disease undergoing percutaneous coronary intervention in routine clinical practice, in whom treatment of a coronary stenosis in a native vessel (de novo lesion or in-stent restenosis) or in a coronary bypass graft with the SeQuent® Sirolimus-Coated Balloon is selected at the operator's discretion. Consecutive, unselected "real-world" patients will be enrolled across participating centers, including a broad range of clinical presentations and anatomical lesion substrates, provided they meet the study eligibility criteria and provide written informed consent.
Trial design
Cohort
Prospective
Treatments tested in this trial
Not listed
Trial groups
Trial outcomes
Primary outcomes
Target Lesion Failure (TLF)
Target lesion failure is defined as the composite of cardiac death, target vessel myocardial infarction (TV-MI) or ischemia-driven target lesion revascularization (TLR), assessed following treatment with the SeQuent® Sirolimus-Coated Balloon in routine clinical practice.
Secondary outcomes
Cardiac death
Cardiac death is defined as any death resulting from an immediate cardiac cause, procedure-related cardiac complications, or any death of unknown cause.
Ischemia-Driven Target Lesion Revascularization (TLR)
Incidence of ischemia-driven target lesion revascularization following treatment with the SeQuent® Sirolimus-Coated Balloon.
Immediate Angiographic Procedural Success
Procedural success defined as residual stenosis ≤30% and absence of flow-limiting dissection (TIMI flow \<3) immediately after the intervention.
Major Adverse Cardiovascular Events (MACE)
Composite of cardiovascular death, non-fatal myocardial infarction, or target lesion revascularization.
Sponsors and contacts
Click on the lead sponsor to view all of their trials.