Safety and Efficacy of Cera™ Patent Foramen Ovale Occluders.

Trial statusRecruiting
Trial phaseNot applicable
Trial typeInterventional
Biological sexAll
Age18-60
SponsorLifetech Scientific (Shenzhen) Co., Ltd.

About this trial

To evaluate the performance of Cera™ patent foramen ovale occluders developed by Lifetech Scientific (Shenzhen) Co., LTD;

Eligibility criteria

This trial does not accept healthy volunteers

Qualifiers

Patients aged 18-60 years;

Be able to understand the purpose of the experiment, voluntarily participate in the experiment and sign the informed consent;

Patent foramen ovale was confirmed by Transthoracic echocardiography (TTE) or Transesophageal echocardiography (TEE);

The presence of medium or large right-to-left shunt was confirmed by Right-heart acoustic contrast (cTTE or cTCD);

Disqualifiers

Carotid atherosclerotic stenosis was determined by the investigator based on CT or vascular ultrasound (> 50%);

Large cerebral infarction occurred within 4 weeks (MR/CT or DWI image ASPECTS score <6 points or infarction volume ≥70 ml or infarction area > 1/3 middle cerebral artery blood supply area);

Patients with intracardiac thrombosis or tumor, intracardiac vegetations;

Acute myocardial infarction or unstable angina within 6 months;

Trial design

Design model

Parallel

Treatments tested in this trial

  • Cera™ patent foramen ovale occluders

    Device

    Patients who meet all the inclusion criteria and don't meet the exclusion criteria will be implanted with the Cera™ patent foramen ovale occluders according to the INSTRUCTIONS for Use (IFU).

  • Another patent foramen ovale occluders

    Device

    Patients who meet all the inclusion criteria and don't meet the exclusion criteria will be implanted with the Another patent foramen ovale occluders according to the INSTRUCTIONS for Use (IFU).

Treatment groups

244 Participants
are divided into 2 treatment groups
Group A: Cera™ patent foramen ovale occludersExperimental treatment 1 intervention
Group B: Another patent foramen ovale occludersActive comparator 1 intervention

Trial outcomes

Primary outcomes

1

Success rate of effective occlusion

Effective occlusion was defined as: 180 days after the surgery, Transthoracic echocardiography (TTE) showed that the position and shape of the occluder were normal, and no horizontal atrial shunt was observed. Re-examination by Contrast transthoracic echocardiography (cTTE) showed no or only a small amount of right-to-left shunt, that is, no microvesicles or less than 10 microvesicles/frame in left heart cavity after Valsalva and resting state.

Time frame
180 days after surgery

Secondary outcomes

1

Success rate of occluder implantation technology

The success of occluder implantation technology is defined as successful intraoperative implantation of occluder and immediate Echocardiography confirmed that the shape and position of the sealing device were appropriate, no new pericardial effusion or valve regurgitation was found, and the perioperative patients survived.

Time frame
7 days after surgery
2

Success rate of surgical implantation of occlusion

Successful occluder implantation was defined as successful implantation of occluder and routine postoperative hospitalization that there were no serious adverse events related to surgery.

Time frame
7 days after surgery
3

Success rate of complete occlusion

Complete occlusion was defined as the Transthoracic echocardiography (TTE) showing occlusion 180 days after surgery The position and shape of the apparatus were normal, and no horizontal atrial shunt was observed. The results of Contrast transthoracic echocardiography (cTTE) were reviewed there was no right-to-left shunt, that is, no microbubbles in the left heart cavity after Valsalva and resting state.

Time frame
180 days after surgery
4

Success rate of effective occlusion

Success rate of effective occlusion was defined as: Transthoracic echocardiography (TTE) showed the position and shape of the occluder 360 days after the operation Normal condition, no horizontal atrial shunt; Reexamination by Contrast transthoracic echocardiography (cTTE) showed no or few results in other words, there were no microbubbles or less than 10 microbubbles in the left heart cavity after Valsalva and resting state.

Time frame
360 days after surgery

Other outcomes

Sponsors and contacts

Click on the lead sponsor to view all of their trials.