Safety and Efficacy of the RENATUS® Transcatheter Aortic Valve System for the Treatment of Severe Aortic Stenosis

Trial statusRecruiting
Trial phaseNot applicable
Trial typeInterventional
Biological sexAll
Age60-100
SponsorBeijing Balance Medical Technology Co., Ltd

About this trial

This study is a prospective, non-randomized, observational, post-market follow-up trial designed to evaluate the safety and efficacy of the RENATUS® Transcatheter Aortic Valve System for the treatment of severe aortic stenosis.

Eligibility criteria

This trial does not accept healthy volunteers

Qualifiers

Patients deemed eligible for TAVR by the treating physician, including those at high, intermediate, or low surgical risk, with a calculated Society of Thoracic Surgeons (STS) risk score;

Mean transvalvular pressure gradient ≥40 mmHg (1 mmHg = 0.133 kPa),

Peak aortic jet velocity ≥4.0 m/s,

Aortic valve area <1.0 cm², or Indexed effective orifice area <0.6 cm²/m²;

Disqualifiers

Patients with a life expectancy of ≤1 year following prosthetic valve implantation;

Patients who have experienced an acute myocardial infarction or undergone any therapeutic cardiac surgery within the past month;

Patients with minimal or no calcification of the aortic annulus;

Patients with aortic root anatomy or pathology deemed unsuitable for prosthetic valve implantation;

Trial design

Design model

Single group

Treatments tested in this trial

  • RENATUS® TAVR

    Device

    RENATUS® Transcatheter Aortic Valve System,an approved marketed TAVR

Treatment groups

800 Participants
are divided into 1 treatment group
Group A: RENATUS® TAVR treatmentExperimental treatment 1 intervention

Trial outcomes

Primary outcomes

1

Cumulative all-cause mortality (all-cause mortality includes both cardiac and non-cardiac deaths)

Time frame
1 year post-procedure

Secondary outcomes

1

Procedural success rate

Time frame
Perioperative
2

Device success rate;

Time frame
Perioperative
3

All-cause mortality at 1, 3, 5, and 10 years

Time frame
1, 3, 5, and 10 years

Other outcomes

1

Transvalvular pressure gradient at 30 days and 1 year post-procedure;

Time frame
30 days and 1 year post-procedure;
2

Valve performance changes: valvular regurgitation, paravalvular leak, etc.;

Time frame
1 year post-procedure
3

Incidence of major adverse cardiovascular and cerebrovascular events (MACCE): death, disabling stroke, myocardial infarction, arrhythmia, conduction block, pacemaker implantation, etc.

Time frame
1, 3, 5, and 10 years
4

Incidence of valve-related complications: infective endocarditis, hemolysis, valve stenosis, prosthetic valve failure, and other manifestations of valve dysfunction

Time frame
1, 3, 5, and 10 years

Sponsors and contacts