Safety and Feasibility of an Integrated Fabric-Type Orthosis for Gait and Balance Improvement in Geriatric Patients

Trial statusRecruiting
Trial phaseNot applicable
Trial typeInterventional
Biological sexAll
Age65+
SponsorSeoul National University Hospital

About this trial

This pilot clinical trial aims to evaluate the safety and feasibility of an integrated fabric-type orthosis with muscle-mimicking and proprioception-enhancing functions in older adults with geriatric conditions affecting gait and balance. The wearable orthosis provides lower-limb assistance through a fabric-based actuation system and vibrotactile proprioceptive stimulation. Thirty participants aged 65 years or older will undergo gait, balance, proprioception, and electromyography assessments under three conditions: without the orthosis, with the orthosis powered off, and with the orthosis powered on. Outcome measures include gait performance, postural sway, one-leg standing balance, joint position sense, muscle activation, physiological responses, fatigue, and device-related adverse events. The study is designed as an exploratory pilot trial to assess the clinical applicability, usability, and safety of the wearable assistive device in geriatric patients.

Eligibility criteria

This trial does not accept healthy volunteers

Qualifiers

Age: Participants must be 65 years of age or older.

Comprehension and Compliance: Able to fully understand and comply with the instructions and study procedures.

Muscle Strength: Handgrip strength of <28 kg for men and <18 kg for women.

Muscle Function: Short Physical Performance Battery (SPPB) score of 8 or less.

Disqualifiers

Inability to Consent: Unable to provide informed consent or not willing to participate in the study procedures.

Severe Sensory or Motion Limitations: Including severe visual or vestibular impairments that could increase the risk of falling.

Communication Barriers: Significant hearing, speech, or language problems that would hinder communication with study personnel.

Independent Walking Inability: Cannot walk independently without the aid of a walking device.

Trial design

Design model

Single group

Treatments tested in this trial

  • Integrated Fabric-Type Orthosis

    Device

    A wearable fabric-type lower-limb orthosis integrating muscle-mimicking actuation and proprioception-enhancing vibrotactile stimulation. The device is designed to assist knee and ankle movements during gait and balance activities in older adults with gait and balance impairments. Participants will be evaluated under three conditions: without the orthosis, with the orthosis powered off, and with the orthosis powered on.

Treatment groups

30 Participants
are divided into 1 treatment group
Group A: Integrated Fabric-Type Orthosis EvaluationExperimental treatment 1 intervention

Trial outcomes

Primary outcomes

1

Change in Blood Pressure From Before to After Functional Assessment

Systolic and Diastolic blood pressure will be measured in millimeters of mercury (mmHg) before and after completion of the functional assessment, which includes gait and balance tests performed under the designated orthosis conditions.

Time frame
Immediately before and after the functional assessment at each study visit
2

Change in Heart Rate From Before to After Functional Assessment

Heart rate will be measured in beats per minute (bpm) before and after completion of the functional assessment, which includes gait and balance tests performed under the designated orthosis conditions.

Time frame
Immediately before and after the functional assessment at each study visit
3

Change in Perceived Exertion From Before to After Functional Assessment

Perceived exertion will be assessed using the Borg Scale before and after completion of the functional assessment. Higher scores indicate greater perceived exertion.

Time frame
Immediately before and after the functional assessment at each study visit
4

Change in Pain Intensity From Before to After Functional Assessment

Pain intensity will be assessed using the Numeric Rating Scale (NRS) before and after completion of the functional assessment. Scores range from 0 to 10, with higher scores indicating greater pain intensity.

Time frame
Immediately before and after the functional assessment at each study visit

Secondary outcomes

1

6-Minute Walk Test

To evaluate walking endurance and functional mobility by measuring the maximum walking distance achieved within six minutes.

Time frame
1.Baseline (before brace application) 2.Immediately post-brace application (power off), 3.Immediately post-brace activation (power on)
2

10-Meter Walk Test

To assess gait speed and short-distance walking performance under different orthosis conditions.

Time frame
1.Baseline (before brace application) 2.Immediately post-brace application (power off), 3.Immediately post-brace activation (power on)
3

20-Meter Walk Test

To assess walking speed and gait performance over a longer walking distance.

Time frame
1.Baseline (before brace application) 2.Immediately post-brace application (power off), 3.Immediately post-brace activation (power on)
4

Surface Electromyography

To evaluate lower-limb muscle activation patterns during walking using surface electromyography (sEMG).

Time frame
1.Baseline (before brace application) 2.Immediately post-brace application (power off), 3.Immediately post-brace activation (power on)

Other outcomes

Sponsors and contacts

Click on the lead sponsor to view all of their trials.

Seoul National University Hospital

Lead sponsor

Ministry of Science and ICT, Republic of Korea

Collaborator