Safety and Performance Assessment of the Sphere-9™ Catheter and Affera™ Ablation System for the Treatment of Ventricular Tachycardia (Sphere-9 VT EFS)

Trial statusRecruiting
Trial phaseNot applicable
Trial typeInterventional
Biological sexAll
Age18-85
SponsorMedtronic Cardiac Ablation Solutions

About this trial

Sphere-9 VT EFS is a prospective, multi-center, non-randomized, unblinded feasibility study. Adult subjects with recurrent, sustained, scar-related monomorphic ventricular tachycardia will be enrolled and treated with the Sphere-9 Catheter and Affera Ablation System.

Eligibility criteria

This trial does not accept healthy volunteers

Qualifiers

Ischemic cardiomyopathy (ICM) patients with prior history of myocardial infarction (MI).

Non-ischemic cardiomyopathy (NICM) patients with documented myocardial scar in a territory without coronary stenosis as evidenced by cardiac imaging.

At least one episode of sustained (continuous for >30 seconds or requiring ICD intervention for termination) monomorphic ventricular tachycardia within the 6 months prior to enrollment.

Recurrence of sustained ventricular tachycardia despite class I or III antiarrhythmic drug therapy or ICD intervention.

Disqualifiers

Incessant VT necessitating hemodynamic support prior to the ablation procedure.

Unstable polymorphic VT or ventricular fibrillation (VF).

Idiopathic VT

Automaticity or triggered activity

Trial design

Design model

Single group

Treatments tested in this trial

  • Sphere-9 Catheter with the Affera Mapping and Ablation System

    Device

    Adult subjects with recurrent, sustained, scar-related monomorphic ventricular tachycardia will be enrolled and undergo ablation with the Sphere-9 Catheter with the Affera Mapping and Ablation System.

Treatment groups

60 Participants
are divided into 1 treatment group
Group A: Ventricular tachycardia catheter ablationExperimental treatment 1 intervention

Trial outcomes

Primary outcomes

1

Primary Safety Endpoint: evaluate the safety of the index ablation procedure

Percentage of patients with device- or procedure-related cardiovascular- or pulmonary-related serious adverse events

Time frame
Within 7 days post-procedure
2

Primary Effectiveness Endpoint: assess acute procedural success of the index ablation procedure

Percentage of patients whose targeted clinically relevant monomorphic ventricular tachycardia cannot be induced

Time frame
Day of ablation procedure

Secondary outcomes

1

Secondary Endpoint: assess chronic effectiveness of the index ablation procedure

Percentage of patients free from recurrence of sustained monomorphic ventricular tachycardia

Time frame
Within 6 months post-procedure

Other outcomes

Sponsors and contacts