About this trial
This research will investigate the safety and usability of the Cionic Neural Sleeve Multistim System for Parkinson's Disease.
Eligibility criteria
This trial does not accept healthy volunteersQualifiers
Self-reported gait impairment
Have access to a smartphone with iOS or Android operating system with Bluetooth capabilities and internet connection
Ability to walk with or without an assistive device for up to 1 minute
Leg measurements within sizing range of the Cionic Neural Sleeve
Disqualifiers
Daily occurrence of falls
Implanted demand-type cardiac pacemaker or defibrillator
Malignant tumor or existing thrombosis in the leg
Fracture or dislocation in the leg that could be adversely affected by motion from stimulation
Trial design
Single group
Treatments tested in this trial
Cionic Neural Sleeve Multistim System
DeviceThe sleeve assists participants during physical activity by delivering electrical stimulation that helps contract the necessary muscles at the correct time to improve movement.
Treatment groups
Trial outcomes
Primary outcomes
Number of Participants Able to Independently Exit a Stimulation Program Using the Cionic Neural Sleeve
Participants' ability to independently exit (terminate) an active stimulation program on the Cionic Neural Sleeve will be assessed during study visits. Independence is defined as successful completion of the task without verbal cueing or physical assistance from study staff. Study staff will document whether the participant is able to exit the program independently (yes/no) at each visit.
Number of Participants Able to Independently Test Stimulation Using the Cionic Neural Sleeve
Participants' ability to independently initiate and test stimulation on the Cionic Neural Sleeve will be assessed during study visits. Successful task completion is defined as the participant correctly activating stimulation and confirming perception of stimulation without assistance. Study staff will document successful independent testing (yes/no).
Number of Participants Able to Independently Calibrate the Cionic Neural Sleeve System
Participants' ability to independently complete device calibration of the Cionic Neural Sleeve system will be assessed during study visits. Calibration is defined as completion of the device-guided calibration procedure without verbal or physical assistance. Study staff will document successful independent calibration (yes/no).
Safety of the Cionic Neural Sleeve
To understand the device's safety profile and potential side effects, researchers will record any adverse events during their home use.
Other outcomes
Qualitative Feedback on Stimulation Timing
Qualitative feedback regarding stimulation timing during gait will be collected every 6 weeks using structured interviews. Data will be used to assess user experience and perceived synchronization between stimulation delivery and functional movement.
Usability of the Cionic Neural Sleeve
Usability of the Cionic Neural Sleeve will be evaluated using the 10-item System Usability Scale with total scores ranging from 0 to 100. Scores greater than or equal to 68 indicate above-average usability.
Impact of the Cionic Neural Sleeve
The Timed Up and Go (TUG) test will be used to assess functional mobility. Participants are instructed to stand up from a chair, walk 3 meters, turn around, return to the chair, and sit down. The total time to complete the task is recorded in seconds, with shorter times indicating better mobility. A minimum clinically important difference (MCID) of 0.77 seconds will be used to interpret meaningful change in performance over time.
Sponsors and contacts
Click on the lead sponsor to view all of their trials.