About this trial
The goal of this observational post-market clinical Follow-up study is to learn about the long-term safety, performance, and clinical benefits of pacing the left bundle branch area (LBBAP) using the INGEVITY+ pacemaker lead in patients with bradycardia who need a pacemaker.
Eligibility criteria
This trial does not accept healthy volunteersQualifiers
Subjects intended to undergo initial (de novo) pacing system implant using the INGEVITY+ lead in the left bundle branch area (LBBA) and a Boston Scientific single or dual- chamber pacemaker (Note: no prior attempted pacing system components);
Symptomatic paroxysmal or permanent second- or third-degree AV block,
Symptomatic bilateral bundle branch block,
Symptomatic paroxysmal or transient sinus node dysfunction with or without associated AV conduction disorders (i.e., sinus bradycardia, sinus arrest, sinoatrial [SA] block),
Disqualifiers
Subjects meeting guideline indications for cardiac resynchronization therapy (CRT) in the absence of a bradycardia indication;
Subjects with a known or suspected sensitivity to dexamethasone acetate (DXA);
Subjects with a Mechanical Tricuspid Valve;
Subjects requiring hemodialysis or peritoneal dialysis;
Trial population
Subjects included in SEPTA PMCF will be selected from the physician investigator's general patient population with a brady pacing indication for single or dual-chamber pacemaker implantation where LBBAP is preferred. Diverse racial and gender patient consideration should be implemented when determining potential participants.
Trial design
Cohort
Prospective
Treatments tested in this trial
Pacemaker lead
DeviceThe pacemaker lead under investigation is a bipolar, steroid-releasing pacemaker electrode with active fixation (IS-1 connection) designed for chronic stimulation and sensing in the right atrium, right ventricle or left bundle branch area (LBBA). In this study, the lead is implanted in the LBBA and connected to a single- or dual-chamber pacemaker. Implantation is performed using a compatible, CE-marked catheter for pacemaker implantation.
Treatment groups
Trial outcomes
Primary outcomes
LBBA Implant Success Rate
Percentage of subjects in whom the INGEVITY+ lead is successfully implanted in the left bundle branch area (LBBA). Implant success is determined by ECG and procedural criteria, as defined per protocol.
Maintenance of Ventricular Synchrony (Paced QRS Duration)
Mean paced QRS duration measured by 12-lead ECG to assess preservation of ventricular synchrony.
Other outcomes
Lead-related Complication-Free Rate
Freedom from lead-related complications (death, serious injury, invasive correction, or permanent loss of device function).