About this trial
The objective of this study is to analyse the positioning of the scapula in standing position and compared to the supine position (CT scan) in 3 dimensions (3 rotations of the scapula) using a non-radiant, portable system, combining an ultrasound probe with marker and a camera integrated into a Tablet for the three-dimensional location of the marker (probe).
Eligibility criteria
This trial does not accept healthy volunteersQualifiers
Major patients and agreeing to participate in the study after oral and written information.
Care course patients for a reverse shoulder arthroplasty on a native shoulder joint
Disqualifiers
Patients under the age of 18
Patients refusing to participate in the study
Patients whose condition does not allow informed consent
Patients who are subject to legal protection (safeguarding of Justice, curatorship, guardianship), persons deprived of their liberty
Trial design
Single group
Treatments tested in this trial
Scapular positioning in Standing position using Sonography
Diagnostic testThe localizer ultrasound of the shoulder is performed in an unclothed patient (at the shoulders) and comes to locate bony landmarks using the ultrasound probe as a Transcutaneous localizer.
Treatment groups
Trial outcomes
Primary outcomes
Study the location of the scapula in 3 dimensions for the patient in standing position
descriptive statistics of the population : mean and standard deviation of the 3 rotations of the scapula in each plane of reference coronal plane expressed in degree. Comparison with the supine position and analysis of any differences.
Study the location of the scapula in 3 dimensions for the patient in standing position
descriptive statistics of the population : mean and standard deviation of the 3 rotations of the scapula in each plane of reference axial plane expressed in degree. Comparison with the supine position and analysis of any differences.
Study the location of the scapula in 3 dimensions for the patient in standing position
descriptive statistics of the population : mean and standard deviation of the 3 rotations of the scapula in each plane of reference sagittal plane expressed in degree. Comparison with the supine position and analysis of any differences.
Secondary outcomes
Evaluating the accuracy of the device using a validation bench
Validation of the device using a biomechanical bench. The rotation will be assessed in coronal plane in degree. The differences between the measurements of the biomechanical bench will be compared to the measurements validation bench to assess the mean error and standard deviation of the ultrasound device
Evaluating the accuracy of the device using a validation bench
Validation of the device using a biomechanical bench. The rotation will be assessed in axial plane in degree. The differences between the measurements of the biomechanical bench will be compared to the measurements validation bench to assess the mean error and standard deviation of the ultrasound device
Evaluating the accuracy of the device using a validation bench
Validation of the device using a biomechanical bench. The rotation will be assessed in sagittal plane in degree. The differences between the measurements of the biomechanical bench will be compared to the measurements validation bench to assess the mean error and standard deviation of the ultrasound device