About this trial
SERENE is an experimental study evaluating low-intensity focused ultrasound neuromodulation of cognitive control circuitry in adults with a lifetime history of suicide attempt or suicidal ideation, but without current suicidality.
Participants will complete screening, cognitive control tasks, MRI/fMRI, ecological momentary assessments, and low-intensity focused ultrasound neuromodulation using the DIADEM system. The study will examine whether low-intensity focused ultrasound (LIFU) neuromodulation changes cognitive control performance measured by the Multi-Source Interference Task (MSIT) and EEG event-related spectral power in the alpha and theta frequency bands.
The study will also examine the time course of LIFU effects and explore whether changes in cognitive control circuitry relate to self-reported experiences, including mood, anxiety, psychosis symptoms, suicidal ideation, and emotion regulation.
Eligibility criteria
This trial does not accept healthy volunteersQualifiers
Lifetime history of suicide attempt or suicidal ideation, as determined by the Columbia-Suicide Severity Rating Scale
Score in specified ranges on measures of cognitive control behavior and/or cognitive control circuit function
No current suicide ideation or behavior within the past 3 months, as determined by the Columbia-Suicide Severity Rating Scale
Age 18 to 65 years
Disqualifiers
Under age 18
Neurological disorder that may affect fMRI scan results or cause reaction to LIFU to differ from healthy adults
Regular use of psychoactive medication, except PRN use if the participant is willing and able to abstain during the study period
Psychiatric hospitalization within the past 3 months
Trial design
Single group
Treatments tested in this trial
DIADEM Low-Intensity Focused Ultrasound Neuromodulation
DeviceLow-intensity focused ultrasound neuromodulation will be delivered using the SPIRE DIADEM device. LIFU will be applied to subregions of deep brain circuitry involved in cognitive control, including regions within the dorsal or ventral internal capsule, surrounding striatal nuclei, and/or connected brain areas. Stimulation will be delivered by trained study staff according to device safety and screening procedures.
Treatment groups
Trial outcomes
Primary outcomes
Mean Reaction Time During the Multi-Source Interference Task Following LIFU at Different Internal Capsule Sites
Cognitive control performance will be assessed using the Multi-Source Interference Task (MSIT), a computerized cognitive control task. Reaction time will be measured in milliseconds. The MSIT will be administered in blocks, with one block corresponding to each internal capsule sonication site. Mean reaction time will be calculated separately for each block and compared with baseline MSIT mean reaction time. Lower reaction times indicate faster task performance.
Event-Related EEG Alpha-Band Spectral Power Following LIFU
EEG alpha-band activity will be assessed using event-related spectral power during the Multi-Source Interference Task (MSIT) following LIFU. Spectral power will be baseline-normalized using a pre-stimulus reference interval from -500 to -100 milliseconds relative to the target event. Baseline normalization will be performed in the linear power domain, with results expressed in decibels (dB).
Event-Related EEG Theta-Band Spectral Power Following LIFU
EEG theta-band activity will be assessed using event-related spectral power during the Multi-Source Interference Task (MSIT) following LIFU. Spectral power will be baseline-normalized using a pre-stimulus reference interval from -500 to -100 milliseconds relative to the target event. Baseline normalization will be performed in the linear power domain, with results expressed in decibels (dB).
Time Course of Mean Reaction Time During the Multi-Source Interference Task Following LIFU
The time course of LIFU effects on cognitive control will be evaluated using repeated mean reaction time measurements obtained during the Multi-Source Interference Task (MSIT). Reaction time will be measured in milliseconds and summarized for each assessment block. Mean reaction time will be compared across the repeated assessments to evaluate changes in cognitive control performance over time. Lower values indicate faster task performance.
Secondary outcomes
Change in MSIT Mean Reaction Time From Baseline Following LIFU at Different Internal Capsule Sites
Differential response to LIFU across internal capsule stimulation sites will be assessed using mean reaction time during the Multi-Source Interference Task (MSIT), measured in milliseconds. Mean reaction time will be calculated separately for the MSIT block corresponding to each sonication site. Change will be calculated as the mean reaction time following sonication at each site minus the baseline mean reaction time. Negative change values indicate faster responses relative to baseline. Changes will be compared across sonication sites.
Change in Momentary Active Suicidal Ideation Rating Measured by Ecological Momentary Assessment
Momentary active suicidal ideation will be assessed using a study-adapted ecological momentary assessment (EMA) item delivered through participants' smartphones. Responses are rated on a 5-point Likert scale from 1 to 5.
Change in Momentary Passive Suicidal Ideation Rating Measured by Ecological Momentary Assessment
Momentary passive suicidal ideation will be assessed using a study-adapted ecological momentary assessment (EMA) item delivered through participants' smartphones. Responses are rated on a 5-point Likert scale from 1 to 5.
Change in Momentary Depression Rating Measured by Ecological Momentary Assessment
Momentary depressive symptoms will be assessed using a study-adapted ecological momentary assessment (EMA) item delivered through participants' smartphones. Responses are rated on a 5-point Likert scale from 1 to 5.
Sponsors and contacts
Click on the lead sponsor to view all of their trials.
This trial is not recruiting at the moment. You can still explore other options: