About this trial
This is an investigator-initiated, multicenter, non inferiority, cluster randomized controlled trial. The primary objective is to compare the diagnostic yield of the electromagnetic robotic assisted bronchoscopy with digital tomosynthesis (Galaxy system by Noah Medical) to the shape sensing robotic assisted bronchoscopy with integrated cone beam CT (Ion™ Endoluminal System by Intuitive) in patients undergoing bronchoscopy for peripheral pulmonary lesion (PPL) evaluation.
Eligibility criteria
This trial does not accept healthy volunteersQualifiers
≥ 18 years of age at time of bronchoscopy
Scheduled for navigational bronchoscopy for the evaluation of pulmonary lesion
Disqualifiers
None
Trial design
Parallel
Treatments tested in this trial
Bronchoscopy for peripheral pulmonary lesion biopsy
Procedure/SurgeryParticipants are scheduled to undergo a bronchoscopy as part of their routine standard of care. Participants will be randomly assigned to one of our two standards of care bronchoscopy robotic platforms (Ion shape sensing robot or Galaxy by Noah electromagnetic robot).
Treatment groups
Trial outcomes
Primary outcomes
Diagnostic yield
Diagnostic yield is defined as the proportion of procedures that results in acquisition of lesional tissue. Lesional tissue is defined by the presence of histopathological findings that readily explain the presence of a pulmonary lesion. The following common histopathological findings are pre-specified as lesional: i. Malignant ii. "Specific benign" findings accounting for the presence of a PPL * organizing pneumonia * purulence * granulomatous inflammation * hamartoma * amyloidoma Procedures with non-specific inflammation, normal tissue, atypia not diagnostic of malignancy, or where no biopsy is obtained due to navigation failure, complication, or equipment failure are non-diagnostic. Only guided bronchoscopy biopsies from the first target lesion are included; non-malignant samples are reviewed by a blinded panel.
Secondary outcomes
Radiation Exposure During Study Bronchoscopy
Radiation exposure is defined as the radiation dose delivered to the patient during the study bronchoscopy, recorded as the dose area product (mGy·cm²). Only radiation directly associated with the index bronchoscopy procedure will be included.
Other outcomes
Duration of Bronchoscopy
Duration of bronchoscopy is defined as the time (in minutes) from insertion of the robotic catheter into the endotracheal tube to removal of the catheter from the endotracheal tube after completion of the procedure.
Need for Additional Diagnostic Procedures
This outcome is defined as any additional diagnostic procedure performed to evaluate the lung lesion of interest after the index bronchoscopy. Procedures include repeat bronchoscopy, transthoracic needle biopsy, or surgical lung biopsy.
Diagnostic Accuracy at 12 Months Post-Bronchoscopy
Diagnostic accuracy is defined as the ability of the index bronchoscopy procedure to correctly identify the pathology of the target lung nodule, as confirmed by clinical follow-up, additional diagnostic procedures, or surgical pathology within 12 months after the biopsy. Both malignant and specific benign diagnoses will be included in the assessment of accuracy.
Specimen Suitability for Molecular Analysis
This outcome assesses whether tissue obtained during the index bronchoscopy procedure is adequate for molecular analysis when clinically indicated. Specimen suitability will be determined based on quantity, quality, and integrity of the tissue for intended molecular testing.