About this trial
The device, a bipolar percutaneous intramuscular electromyography electrode, is intended for use in upper-limb amputation patients who have received the regenerative peripheral nerve interface surgical procedure, in order to enable the use of advanced prosthetic arms and hands.
Eligibility criteria
This trial does not accept healthy volunteersQualifiers
Participants must be 22 years of age or older.
Participants must have previously undergone an upper limb amputation proximal to the wrist or are scheduled to undergo an upper limb amputation proximal to the wrist.
For participants without existing RPNI grafts (at the time of enrollment), the residual limb must have sufficient soft tissue quality to support performance of the RPNI operative procedure. Participants sustaining severe crushing or avulsion injuries with substantial superficial and deep scarring may not be appropriate candidates for inclusion in the study.
Participants must be in good health and American Society of Anesthesiologists (ASA) Class I or II (low surgical risk).
Disqualifiers
Participants may not be suffering from any severe pain syndrome including complex regional pain syndrome or severe phantom pain. All of these conditions would suggest pathological activity of the nerve and would exclude the participant from participation.
Participants must not be suffering from any untreated mental health disorders and if they have any DSM-5 diagnoses, they must receive approval to participate from their mental health professional.
Participants must not have any medical conditions that, in the opinion of the Principal Investigator, would place them at high risk for a surgical procedure including recent myocardial infarction, cerebrovascular accidents, deep venous thrombosis, pulmonary embolus, uncontrolled diabetes, or end stage renal disease.
Participants must not have used tobacco for at least one month prior to enrollment in the study.
Trial design
Parallel
Treatments tested in this trial
a bipolar percutaneous intramuscular electromyography electrode
DeviceThe device, a bipolar percutaneous intramuscular electromyography electrode, is intended for use in upper-limb amputation patients who have received the regenerative peripheral nerve interface surgical procedure, in order to enable the use of advanced prosthetic arms and hands.
Treatment groups
Trial outcomes
Primary outcomes
Change in Pain Level as measured by SF-36
Pain will be assessed using the SF-36 survey instrument, to be filled out by the participant before and after each surgical procedure performed and at a minimum of once per month while electrodes remain implanted. Two questions related to pain with a score closer to 0 means a pain increase
Change in Pain Level as measured by LANSS survey
Pain will be assessed using the LANSS survey instrument, to be filled out by the participant before and after each surgical procedure performed and at a minimum of once per month while electrodes remain implanted. A score greater than 12 indicates neuropathic pain.
Change in Pain Level as measured by Phantom Limb Questionnaire
Phantom pain will be assessed using the Phantom Limb Questionnaire, to be filled out by the participant before and after each surgical procedure performed and at a minimum of once per month while electrodes remain implanted. This 9-item instrument measures phantom pain on a scale of 0-4, where 0-no pain at all and 4=very severe pain.
RPNI tissue degeneration measured by pain scores
RPNI tissue degeneration will be assessed by changes in pain scores (see above) and measurements of recording efficacy. Recording efficacy will be assessed using two signal quality measures: 1. Peak-to-peak signal amplitude during maximum voluntary contraction 2. Signal-to-noise ratio during maximum voluntary contraction
Secondary outcomes
EMG signal quality from RPNI grafts
Efficacy will be assessed, for each implanted electrode using two calculated signal quality measures: Peak-to-peak signal amplitude during maximum voluntary contraction and signal-to-noise ratio during maximum voluntary contraction.
Stimulation Threshold of RPNI grafts
Stimulation data will be recorded at least once per month while electrodes remain implanted. Stimulation threshold will be determined using the range of sensory feedback necessary to evoke a sensory percept.
Sponsors and contacts
Click on the lead sponsor to view all of their trials.
University of Michigan
Lead sponsor
National Institute of Neurological Disorders and Stroke (NINDS)
Collaborator
Eunice Kennedy Shriver National Institute of Child Health and Human Development (NICHD)
Collaborator