About this trial
This is a prospective, multicenter, single-group, target value clinical trial planning to enroll 208 eligible subjects. Participants will be treated with the investigational carotid artery stent system and followed up at discharge, 30 days, 6 months, and 12 months postoperatively to evaluate the safety and efficacy of the device for endovascular treatment of carotid artery stenosis.
Eligibility criteria
This trial does not accept healthy volunteersQualifiers
Age ≥18 years, either sex.
Preoperative carotid duplex ultrasound (DUS) confirms stenosis of the common carotid artery (CCA), internal carotid artery (ICA), or carotid bifurcation, and the subject is deemed suitable for endovascular intervention.
Intraoperative digital subtraction angiography (DSA) confirms symptomatic carotid artery stenosis ≥50% or asymptomatic carotid artery stenosis ≥80% (measured by NASCET criteria). Symptomatic is defined as a non-disabling ischemic stroke or transient ischemic attack (TIA), including cerebral hemisphere events or amaurosis fugax, occurring within 6 months prior to the procedure.
Reference vessel diameter at the target lesion ranges from 3.5 mm to 9.5 mm.
Disqualifiers
Target lesion caused by carotid arteritis.
Target lesion located at the ostium of the common carotid artery.
Severe, long-segment calcification or severe tortuosity at the target lesion preventing adequate stent delivery.
Target lesion is a complete occlusion.
Trial design
Single group
Treatments tested in this trial
Carotid Artery Stenting
DeviceAll participants will undergo carotid artery stenting (CAS).
Treatment groups
Trial outcomes
Primary outcomes
Incidence of In-Stent Restenosis (ISR)
Restenosis is defined as ≥50% diameter stenosis occurring within the stent or within 5 mm of the proximal or distal stent edge of the target carotid artery, as assessed by carotid duplex ultrasound (DUS).
Incidence of Major Adverse Events (MAE)
Major adverse events (MAE) are defined as the composite incidence of: (1) death, stroke (ischemic or hemorrhagic), or myocardial infarction (MI) occurring within 30 days after the procedure; and (2) death or ipsilateral ischemic stroke of the target vessel occurring from 31 to 365 days after the procedure.
Secondary outcomes
Device Success Rate
Defined as the percentage of enrolled subjects in whom device success is achieved. Device success is defined as successful implantation (including delivery, deployment, and expansion) of the stent covering the target lesion, with successful retrieval of the delivery system.
Procedural Success Rate
Defined as the percentage of enrolled subjects in whom procedural success is achieved. Procedural success is defined as successful implantation of the stent, with post-procedure angiography demonstrating ≤30% residual stenosis at the target lesion, and freedom from major adverse events (MAE; defined as all-cause death, stroke, or myocardial infarction) prior to hospital discharge.
Incidence of In-Stent Restenosis (ISR)
Defined as the percentage of enrolled subjects who develop ISR at 6 months post-procedure. ISR is defined as restenosis within the stent or within 5 mm proximal or distal to the stent edge of the target carotid artery, as assessed by carotid duplex ultrasound (DUS), with DUS criteria indicating ≥50% diameter stenosis.
Incidence of Target Lesion Revascularization (TLR)
The percentage of enrolled subjects who undergo TLR within 30 days, at 6 months, and at 12 months post-procedure. TLR is defined as any repeat revascularization (including any surgical or percutaneous intervention) of the target lesion after the initial index procedure.
Sponsors and contacts
Click on the lead sponsor to view all of their trials.
Suzhou Zenith Vascular SciTech Limited
Lead sponsor
Xuanwu Hospital, Beijing
Collaborator
This trial is not recruiting at the moment. You can still explore other options: