About this trial
The SSW-DCB study will test whether a slow balloon inflation technique reduces the need for a stent during a coronary procedure in adults with coronary artery disease who are scheduled for drug-coated balloon treatment.
Before using a drug-coated balloon, doctors use a separate balloon to prepare the narrowed area of the artery. Participants will be assigned by chance to one of two groups, with an equal chance of joining either group. In one group, doctors will use the Slow Up, Slow Down, and Wait (SSW) technique, which involves gradually increasing the balloon pressure, holding it briefly, and then gradually releasing the pressure. In the other group, doctors will use the usual balloon inflation technique.
After preparing the artery, doctors will check whether it is suitable for treatment with a drug-coated balloon. If the artery meets the study criteria for needing a stent, a stent may be placed during the procedure. This is called bailout stenting. The main question is whether fewer participants in the SSW group need bailout stenting.
Follow-up visits or calls are planned at 1, 6, 9, and 12 months after the procedure. A repeat coronary angiogram is planned at 12 months to check the treated area. Longer-term follow-up will collect information about heart-related and bleeding events.
Eligibility criteria
This trial does not accept healthy volunteersQualifiers
Age 18 years or older.
Clinical diagnosis of coronary artery disease presenting as chronic coronary syndrome or hemodynamically stable acute coronary syndrome.
Diameter stenosis of 70% or greater by quantitative coronary angiography (QCA).
Diameter stenosis of 50% to 69% by QCA with functional evidence of ischemia, such as a positive fractional flow reserve (FFR) or instantaneous wave-free ratio (iFR) result, or clear evidence of ischemia based on clinical findings or noninvasive testing.
Disqualifiers
Hemodynamic instability, such as persistent hypotension or a need for vasopressors or mechanical circulatory support.
Left main coronary artery lesion or bifurcation lesion.
Severe comorbidity, such as active malignancy or severe hepatic or renal failure, or inability to complete follow-up.
Chronic total occlusion, severe calcification requiring rotational atherectomy, or severe tortuosity greater than 90 degrees in the target lesion.
Trial design
Parallel
Treatments tested in this trial
Slow Up, Slow Down, and Wait Balloon Inflation
Procedure/SurgeryDuring coronary lesion preparation, the operator initially inflates the balloon to unfold it, then increases pressure at 2 atmospheres per second to the target pressure. The operator holds the target pressure for 5 to 10 seconds and then releases pressure at no more than 2 atmospheres per second until it reaches zero.
Routine Balloon Inflation
Procedure/SurgeryDuring coronary lesion preparation, the operator increases balloon pressure rapidly and continuously to the target pressure over 3 to 5 seconds, holds the target pressure for 5 to 10 seconds, and then deflates the balloon by applying negative pressure with the inflation device.
Treatment groups
Trial outcomes
Primary outcomes
Percentage of Participants Undergoing Intraprocedural Bailout Stenting
The percentage of participants who receive at least one bailout stent during the index coronary intervention because the protocol-defined criteria for bailout stenting are met.
Secondary outcomes
Percentage of Participants Requiring Repeat Revascularization
Percentage of participants requiring repeat revascularization within 24 hours after the index coronary intervention.
Percentage of Participants With Angiographic Restenosis
Percentage of participants with greater than 50% diameter stenosis in the target lesion on follow-up quantitative coronary angiography. Assessed separately in participants ultimately treated with a drug-coated balloon and those ultimately treated with a drug-eluting stent.
Cumulative Incidence of Target Lesion Failure
Target lesion failure is a composite of cardiac death, target vessel myocardial infarction, or clinically driven target lesion revascularization. The 12-month cumulative incidence will be estimated separately in the drug-coated balloon and drug-eluting stent cohorts.
Cumulative Incidence of Cardiac Death
Cardiac death is an individual component of target lesion failure and will be reported separately in the drug-coated balloon and drug-eluting stent cohorts.
Other outcomes
Percentage of Participants With Plaque Regression
Among participants with paired intravascular imaging, the percentage with a decrease in plaque burden of at least 5 percentage points from immediately after the index intervention to 12 months. Measurements are based on blinded core laboratory readings.
Change in Plaque Volume
The 12-month plaque volume minus the immediate post-procedure plaque volume, expressed in cubic millimeters. This is a supportive measure of plaque regression in the paired intravascular imaging subgroup.
Change in Percent Atheroma Volume
The 12-month percent atheroma volume minus the immediate post-procedure percent atheroma volume, expressed in percentage points. This is a supportive measure of plaque regression in the paired intravascular imaging subgroup.
Sponsors and contacts
Click on the lead sponsor to view all of their trials.
China National Center for Cardiovascular Diseases
Lead sponsor
Shanghai Shenqi Medical Technology Co., Ltd
Collaborator
This trial is not recruiting at the moment. You can still explore other options: