Spinal Cord Blood Flow Measurement

Trial statusNot yet recruiting
Trial phaseNot applicable
Trial typeInterventional
Biological sexAll
Age18-70
SponsorUniversity of Calgary

About this trial

The purpose of this study is to measure spinal cord blood flow in participants with acute cervical or high-thoracic spinal cord injury. During planned spinal cord decompression surgery after acute spinal cord injury, participants will have a blood flow sensor placed around the area of injury. The participant's breathing rate and depth, which is controlled via a ventilator as part of standard surgical care, will be manipulated to test whether progressively increasing carbon dioxide levels increases spinal cord blood flow. This will provide the first safety data of the effects of altering carbon dioxide intraoperatively for spinal cord injury.

Eligibility criteria

This trial does not accept healthy volunteers

Qualifiers

Age 18-70 presenting with acute SCI between C4-T6

Requiring surgical decompression, with or without instrumentation

Able to be mechanically ventilated under general anaesthesia for the surgical procedure

Able to provide informed consent, or with a legally authorized/substitute decision-maker able to provide consent where the participant has impaired capacity in the acute setting, with ongoing consent obtained from the participant following completion of the surgical procedure. Enrollment occurs in the acute setting where capacity may be temporarily impaired

Disqualifiers

Known or suspected traumatic brain injury

Severe multi-systemic injury or chest trauma

Hemodynamically unstable, or otherwise ineligible for surgery

Confirmed pregnancy

Trial design

Design model

Parallel

Treatments tested in this trial

  • Ventilatory manipulation

    Other intervention

    Participants will be receiving mechanical ventilation as part of their standard care. The clinical operating team, specifically the attending anesthesiologist, will adjust their level of ventilation (breathing rate, depth) to achieve predetermined levels of end-tidal CO2. Spinal cord oxygenation will be measured in all participants before, during, and after ventilatory manipulation.

Treatment groups

16 Participants
are divided into 2 treatment groups
Group A: Ventilatory manipulationExperimental treatment 1 intervention
Group B: ControlNo intervention 0 interventions

Trial outcomes

Primary outcomes

1

Spinal cord tissue oxygenation during intraoperative monitoring

Spinal cord tissue oxygenation, measured as tissue partial pressure of oxygen (PtO₂) using the Integra LICOX monitoring system, recorded continuously during the intraoperative monitoring period in both arms. In the intervention arm, PtO₂ is assessed across stepwise end-tidal CO₂ levels (35, 45, 55, 65 mmHg, held approximately five minutes each) to characterise the dose-response relationship between end-tidal CO₂ and spinal cord tissue oxygenation. In the comparison arm, PtO₂ is recorded under standard care without CO₂ manipulation to provide reference values.

Time frame
Intraoperative, during the ventilatory titration protocol (approximately 20 to 30 minutes), from pre-titration baseline through each end-tidal CO₂ level (35, 45, 55, 65 mmHg).

Secondary outcomes

1

Incidence of peri- and post-operative adverse events

Incidence, type, and severity of peri- and post-operative adverse events (for example, arrhythmias, acid-base disturbance, hemodynamic instability), abstracted from the medical record and coded in alignment with the NINDS Common Data Elements. Events are summarised by arm and by relationship to the study procedures, to assess the safety of intraoperative end-tidal CO₂ titration.

Time frame
From surgery through acute hospital discharge (up to approximately 30 days).
2

Systemic blood pressure during intraoperative monitoring

Systemic blood pressure (mean arterial pressure) recorded continuously during the intraoperative monitoring period in both arms. In the intervention arm, values are assessed across stepwise end-tidal CO₂ levels (35, 45, 55, 65 mmHg) to characterise the hemodynamic response to ventilatory CO₂ manipulation. In the comparison arm, values are recorded under standard care without CO₂ manipulation to provide reference values.

Time frame
Intraoperative, during the ventilatory titration protocol (approximately 20 to 30 minutes).
3

Arterial carbon dioxide during intraoperative monitoring

Arterial blood gas values (PaCO₂, PaO₂, pH) measured from the arterial line and recorded continuously during the intraoperative monitoring period in both arms. In the intervention arm, values are assessed across stepwise end-tidal CO₂ levels (35, 45, 55, 65 mmHg) to confirm the achieved degree of hypercapnia and to monitor acid-base status (protocol conducted only while pH ≥ 7.3). In the comparison arm, values are recorded under standard care without CO₂ manipulation.

Time frame
Intraoperative, during the monitoring period (approximately 20 to 30 minutes).
4

Heart rate during intraoperative monitoring

Heart rate (beats per minute) recorded continuously during the intraoperative monitoring period in both arms. In the intervention arm, values are assessed across stepwise end-tidal CO₂ levels (35, 45, 55, 65 mmHg) to characterise the hemodynamic response to ventilatory CO₂ manipulation. In the comparison arm, values are recorded under standard care without CO₂ manipulation to provide reference values.

Time frame
Intraoperative, during the ventilatory titration protocol (approximately 20 to 30 minutes).

Other outcomes

Sponsors and contacts

Click on the lead sponsor to view all of their trials.

This trial is not recruiting at the moment. You can still explore other options: