About this trial
This study aims to directly compare and contrast swallowing pressure and impedance measurements obtained from two high-resolution manometry (HRM) systems: the Laborie LMT Pharyngeal System and the Medtronic ManoScan ESO HRM System in healthy adult volunteers. The primary objective is to determine how differences in catheter diameter, sensor configuration, and acquisition platforms influence measurement outcomes. Twenty-five healthy adults will participate in a single, approximately 2-hour visit; the study will be open for one year for data collection and two years for data analysis.
Eligibility criteria
This trial accepts healthy volunteersQualifiers
without known swallowing disorders
Disqualifiers
Known swallowing disorder
Allergy to topical anesthetic
Allergy to food relevant to study participation (e.g. lactose intolerance)
Inability to follow direction or remain calm during the experiment.
Trial design
Crossover
Treatments tested in this trial
Laborie LMT Pharyngeal System (3.7 mm catheter)
DeviceThe Solar GI HRM system is intended to record, store, view, and analyze pressure, impedance, EMG, swallow and respiration, and various auxiliary input device data online anywhere in the gastrointestinal tract (pharynx; esophagus; stomach; duodenum; sphincter of Oddi; small bowel; colon and anorectal area, including rectum and pelvic floor) to assist in the diagnosis and evaluation of gastrointestinal and swallowing disorders. Used with 3.7 mm catheter.
Medtronic ManoScan ESO HRM System (4.2 mm catheter)
DeviceThe ManoScan™ ESO high resolution manometry system enables full evaluation of the motor functions of the esophagus. The system provides useful information to support diagnosis of conditions like dysphagia, achalasia, and hiatal hernia. A 36-channel circumferential solid-state catheter with 4.2 mm diameter, 1.0 cm spacing between adjacent sensors.
Treatment groups
Trial outcomes
Primary outcomes
Base of tongue pressure
Measured with both Laborie HRM impedance system and Medtronic HRM impedance system for comparison.
Hypopharyngeal peak pressure
Measured with both Laborie HRM impedance system and Medtronic HRM impedance system for comparison.
Pharyngeal Contractile Integral (PhCI)
Measured with both Laborie HRM impedance system and Medtronic HRM impedance system for comparison.
Pressure rise time
Measured with both Laborie HRM impedance system and Medtronic HRM impedance system for comparison.