About this trial
The goal of this clinical trial is to learn if a chin strap helps reduce low oxygen episodes in premature babies receiving CPAP or NIPPV (breathing support through the nose). The main question it aims to answer is:
Does wearing a chin strap during CPAP or NIPPV make low oxygen episodes shorter compared to not wearing one?
Researchers will compare the chin strap period to the no-chin-strap period to see if the chin strap shortens low oxygen episodes.
Participants will:
Be randomly assigned to wear the chin strap first or skip it first Wear a soft chin strap for 24 hours, then switch to no chin strap for 24 hours (or the reverse), with a 1-hour break in between Have continuous monitoring of oxygen levels, heart rate, and breathing throughout the 49-hour study
Eligibility criteria
This trial does not accept healthy volunteersQualifiers
Gestational age less than 32 weeks at birth
Less than 34 weeks postmenstrual age (PMA) at enrollment
Receiving CPAP or NIPPV with PEEP of 5-10 cmH₂O
FiO₂ 0.40 or less
Disqualifiers
Major congenital anomalies
Craniofacial abnormalities affecting chin strap fit or mouth closure
Active seizures
Imminent need for intubation as determined by the treating clinician
Trial design
Crossover
Treatments tested in this trial
Chinstrap
DeviceA soft, commercially available chin strap (Neotech ChinStrap, Neotech Products LLC) applied to maintain gentle mouth closure during CPAP/NIPPV in preterm infants. Size is selected based on head circumference measurement. The device is made of soft, breathable NeoFoam material, is latex-free, and is for single patient use. It is applied by nursing staff and assessed hourly for proper positioning and skin integrity.
Treatment groups
Trial outcomes
Primary outcomes
IH80 Duration Per Event (IH80dpe)
Average duration per intermittent hypoxemia event with SpO₂ below 80% for at least 10 seconds (IH80dpe), measured in seconds per event per 24-hour study period. Calculated as total cumulative duration of SpO₂ below 80% events divided by the number of events in the 24-hour period.
Secondary outcomes
IH80 Frequency
Number of intermittent hypoxemia events with SpO₂ below 80% for at least 10 seconds per 24-hour study period
IH85 Frequency
Number of intermittent hypoxemia events with SpO₂ below 85% for at least 10 seconds per 24-hour study period
IH85 Duration Per Event (IH85dpe)
Average duration per intermittent hypoxemia event with SpO₂ below 85% for at least 10 seconds, in seconds per event per 24-hour study period
IH90 Frequency
Number of intermittent hypoxemia events with SpO₂ below 90% for at least 10 seconds per 24-hour study period
Other outcomes
Severe Bradycardia Frequency (Exploratory)
Number of severe bradycardia episodes (heart rate below 80 bpm for at least 10 seconds) per 24-hour study period. High within-subject variance is expected; this outcome will be analyzed as exploratory and descriptive only