STRIVE Post-Market Registry Study

ConditionEmphysema
Trial statusRecruiting
Trial phaseNot listed
Trial typeObservational
Biological sexAll
Age18+
SponsorOlympus Corporation of the Americas

About this trial

This is a single-arm, prospective, multi-center, Registry study to evaluate the long-term safety and effectiveness of the Spiration Valve System (SVS) for the treatment of severe emphysema in a post-market setting.

Eligibility criteria

This trial does not accept healthy volunteers

Qualifiers

Adult patients with shortness of breath and hyperinflation associated with severe emphysema and evidence of low collateral ventilation.

Subjects must understand and voluntarily sign an informed consent form.

Disqualifiers

Subjects who are not appropriate for SVS therapy based upon the US FDA-approved IFU requirements.

Subjects who were withdrawn from this study for any reason will not be allowed to re-enroll.

Subjects who have incomplete screening or baseline data.

Trial population

Adult patients with shortness of breath and hyperinflation associated with severe emphysema in regions of the lung that have evidence of low collateral ventilation.

Trial design

Design model

Cohort

Time perspective

Prospective

Treatments tested in this trial

  • Spiration Valve System (SVS)

    Device

    Spiration Valves are one-way endobronchial valves indicated for adult patients with shortness of breath and hyperinflation associated with severe emphysema in regions of the lung that have evidence of low collateral ventilation. The Spiration Valve is loaded in the deployment catheter, then passed through the channel of a flexible bronchoscope and deployed at the intended target location. The SVS device is designed to relieve the symptoms of shortness of breath and hyperinflation associated with severe emphysema without surgery.

Treatment groups

No treatment groups listed

Trial outcomes

Primary outcomes

1

Incidence of pre-specified thoracic adverse events of special interest (TAEsSI) through 12 months following the first implantation procedure

The primary safety endpoint will be the incidence of device-related and procedure-related pre-specified thoracic adverse events of special interest (TAEsSI) through 12 months following the first implantation procedure.

Time frame
12 months
2

Rate (per patient-year) of pre-specified thoracic adverse events of special interest (TAEsSI) through 36 months following the first implantation procedure

An additional analysis will present the rate (per patient-year) of TAEsSI.

Time frame
36 months

Secondary outcomes

1

45-day pneumothorax rate

45-day pneumothorax rate, defined as pneumothorax requiring surgical intervention, or prolonged air leak \> 7 days defined as the time from chest tube insertion to the time the air leak is not present.

Time frame
45 days
2

Survival rate over 24 months

Survival rate over 24 months compared to the EMPROVE study control cohort

Time frame
24 months

Other outcomes

1

Targeted lobe volume reduction (TLVR)

Target lobe volume reduction (TLVR) determined from quantitative High-Resolution Computed Tomography (HRCT) at 6 months

Time frame
6 months
2

Hyperinflation

It will be measured by the ratio of residual volume to total lung capacity (RV/TLC) using plethysmography from baseline

Time frame
6 and 12 months
3

Forced expiratory volume in 1 second (FEV1)

Relative (percentage) change from baseline at 6, 12, 24 and 36 months

Time frame
6, 12, 24 and 36 months
4

Modified Medical Research Council (mMRC) change

Modified Medical Research Council (mMRC) change from baseline at 6, 12, 24 and 36 months

Time frame
6, 12, 24 and 36 months

Sponsors and contacts

Click on the lead sponsor to view all of their trials.