Stryker Photon Blade 3 Outcomes

ConditionLumpectomy
Trial statusNot yet recruiting
Trial phaseNot listed
Trial typeObservational
Biological sexAll
Age18+
SponsorThe Cleveland Clinic

About this trial

The PhotonBlade 3 Smoke Evacuation device is a monopolar RF device coupled with illumination that is FDA approved and indicated for cutting and coagulation of soft tissue during surgical procedures and for removing smoke generated by electrosurgery when used in conjunction with an effective smoke evacuation system. The device includes a coated electrode at the distal end of a rotatable and extendable shaft (telescope) which delivers monopolar radiofrequency energy for cutting and coagulation of tissue. These devices enable the operator to remotely conduct an electrosurgical current from the output connector of an electrosurgical unit (ESU) to the operative site for the desired surgical effect. The integrated LED-based illumination allows the user to turn on or off the illumination. The integrated smoke evacuation tubing enables the user to evacuate smoke generated by electrosurgery when used in conjunction with an effective smoke evacuation system.

The Photon Blade 3 integrates localized surgical field illumination, simultaneous electrosurgical dissection, and active smoke evacuation. By improving visualization at the point of dissection and reducing smoke plume accumulation, surgeons perform more precise tissue dissection and hemostasis. The Photon Blade 3 device is FDA approved and being used in standard clinical care at Cleveland Clinic per its intended use. Utilization of the Photon Blade 3 expands feasibility of hidden scar lumpectomy approaches without compromising tissue handling. Cosmetic outcome after lumpectomy significantly influences patient satisfaction, body image, and quality of life. Reduced tissue trauma, optimized hemostasis, and improved control of the resection cavity translate into preservation of native breast contour, potentially leading to lower incidence of fat necrosis with less thermal injury, and more discrete scar placement.

The overall goal of this study is to assess the clinical performance and safety of the Photon Blade 3 illuminated electrosurgical device with integrated smoke evacuation, including patient reported outcomes, incorporation of oncoplastic techniques, and surgical field optimization. This study allows for the collection of data from cases where the device is already being used in standard clinical care in accordance with its FDA approved indication.

Eligibility criteria

This trial does not accept healthy volunteers

Qualifiers

any adult patient (18 years of age or older) undergoing lumpectomy for benign or atypical disease with PI as surgeon at Avon or Fairview Hospital

Disqualifiers

Malignancy

Trial population

lumpectomy for benign or atypical disease

Trial design

Design model

Case-only

Time perspective

Prospective

Treatments tested in this trial

Not listed

Trial groups

No trial groups listed

Trial outcomes

Primary outcomes

1

Degree of clinical performance assess at the time of surgery by the operative success rate and occurrence of intraoperative complications.

Operative success determined by whether target lesion was excised.

Time frame
time of surgery
2

Postoperative complication rate assessed by the occurrence of pre-specified AE's at 3 days post-op, 2 weeks post-op, 45 days post-op and 90 days post-op.

The pre-specified AE's are seromas, hematomas, wound dehiscence and surgical site infections requiring antibiotics.

Time frame
up to 90 days post-op

Secondary outcomes

Other outcomes

Sponsors and contacts

Click on the lead sponsor to view all of their trials.

The Cleveland Clinic

Lead sponsor

Stryker Instruments

Collaborator