Study of Transcatheter Aortic Valve Replacement With A² Flex and Commissural Alignment Technology in Severe Aortic Stenosis

Trial statusNot yet recruiting
Trial phaseNot applicable
Trial typeInterventional
Biological sexAll
Age60+
SponsorPeijia Medical Technology (Suzhou) Co., Ltd.

About this trial

A prospective, single-center, single-group follow-up study of transcatheter aortic valve replacement with A² Flex and commissural alignment technology in severe aortic stenosis by Peijia Medical

Eligibility criteria

This trial does not accept healthy volunteers

Qualifiers

Patients who are willing to participate and sign the informed consent and can cooperate with the whole trial process;

Age ≥60 years old;

Patients with severe calcified aortic stenosis confirmed by echocardiography (trans-aortic valve flow velocity ≥ 4.0m /s, or trans-active valvular pressure difference ≥40mmHg (1mmHg=0.133kPa), or aortic valve orientation area < 0.8cm2, or effective aortic valve orifice the product index is < 0.5cm2/m2);

The cardiac team (at least two specialists in cardiovascular surgery) assessed the patient as unsuitable for routine surgery ;

Disqualifiers

The left and right coronary ostiums originate from the junctional zone or from both coronary ostiums;

previous CABG history;

Coronary ostial lesions(PCI or not);

Prior aortic valve prosthesis implantation (interventional/surgical, bioprosthetic/mechanical);

Trial design

Design model

Single group

Treatments tested in this trial

  • transcatheter aortic valve replacement in severe aortic stenosis

    Device

    transcatheter aortic valve replacement with A² Flex and commissural alignment technology in severe aortic stenosis

Treatment groups

10 Participants
are divided into 1 treatment group
Group A: A single arm studyExperimental treatment 1 intervention

Trial outcomes

Primary outcomes

1

Device success rate

Device success is defined as - Vascular access, artificial aortic valve delivery and release were successful, and the delivery catheter was successfully withdrawn. - The artificial aortic valve was implanted in an anatomically accurate position. - The artificial aortic valve met the expected requirements (mean transvalvular pressure difference \< 20mmHg or maximum flow rate \< 3m/s; Doppler velocity index \>\_0.25,and less than moderate aortic regurgitation)

Time frame
at 30 days

Secondary outcomes

Other outcomes

Sponsors and contacts

Click on the lead sponsor to view all of their trials.

Peijia Medical Technology (Suzhou) Co., Ltd.

Lead sponsor

Shanghai Zhongshan Hospital

Collaborator

This trial is not recruiting at the moment. You can still explore other options: