Study on the Safety and Effectiveness of a Biodegradable Patent Foramen Ovale Occluder System

Trial statusNot yet recruiting
Trial phaseNot applicable
Trial typeInterventional
Biological sexAll
Age18-65
SponsorShanghai Lingsi Medical Technology Co., Ltd.

About this trial

To evaluate the Safety and Efficacy of a Novel Biodegradable Occluder for Percutaneous Closure of Patent Foramen Ovale (PFO)

Eligibility criteria

This trial does not accept healthy volunteers

Qualifiers

Aged between 18 and 65 years.

Presence of a patent foramen ovale (PFO) confirmed by transthoracic echocardiography (TTE) or transesophageal echocardiography (TEE).

Presence of a moderate-to-large right-to-left shunt (RLS) at rest or during the Valsalva maneuver, as confirmed by agitated saline contrast echocardiography (also known as bubble study).

Clinically diagnosed with a PFO-associated ischemic stroke or transient ischemic attack (TIA).

Disqualifiers

An alternative, clearly identified cause of ischemic stroke or TIA (other than PFO) is determined by the investigator.

Large territory cerebral infarction within 4 weeks prior to the planned procedure.

Atherosclerotic stenosis (>50%) of the carotid or vertebral arteries, as confirmed by CT angiography or vascular ultrasound per investigator assessment.

Presence of intracardiac thrombus or vegetation as confirmed by echocardiography.

Trial design

Design model

Parallel

Treatments tested in this trial

  • Active Comparator

    Device

    Percutaneously occlusion of PFO with Cardi-o-fix PFO occluder

  • Experimental

    Device

    Transcatheter closure of a patent foramen ovale (PFO) with biodegradable PFO occluder

Treatment groups

258 Participants
are divided into 2 treatment groups
Group A: Cardi-o-fix PFO occluderActive comparator 1 intervention
Group B: Biodegradable PFO occluder systemExperimental treatment 1 intervention

Trial outcomes

Primary outcomes

1

Success rate of effective occlusion

Effective occlusion was defined as: 12 months after the procedure, Echocardiographyshowed that the position and shape of the occluder were normal, and no horizontal atrial shunt was observed. Re-examination by Contrast echocardiography (cTTE or cTEE) showed no or only a small amount of right-to-left shunt, that is, no microvesicles or less than 10 microvesicles/frame in left heart cavity after Valsalva and resting state.

Time frame
at 12 months post-implantation

Secondary outcomes

1

Success rate of effective occlusion

Effective occlusion was defined as: 6 months after the procedure, Echocardiographyshowed that the position and shape of the occluder were normal, and no horizontal atrial shunt was observed. Re-examination by Contrast echocardiography (cTTE or cTEE) showed no or only a small amount of right-to-left shunt, that is, no microvesicles or less than 10 microvesicles/frame in left heart cavity after Valsalva and resting state.

Time frame
at 6 months post-implantation
2

Device Success Rate

Successful intraoperative deployment of the occluder, with immediate post-procedure echocardiography confirming appropriate device morphology and position, absence of new pericardial effusion or valvular regurgitation, and successful retrieval of the delivery system

Time frame
immediately after the procedure
3

Procedural success Rate

Successful device implantation without any procedure- or device-related complications prior to discharge. Complications include atrial fibrillation, other serious arrhythmic events, thrombosis, cerebral embolism, pericardial effusion, cardiac tamponade, device embolization, or displacement

Time frame
at discharge or 7 days post-procedure
4

Recurrence or incidence of cryptogenic stroke or TIA

Cryptogenic stroke was defined as a new focal cerebral ischemia confirmed by neuroimaging (cranial MRI or CT), which was performed After extensive vascular, cardiac, and blood evaluation, non-atherosclerotic, cardiogenic, or arteriolar obliterators were identified Cerebral infarction caused by the diagnosis of exclusion.

Time frame
From attempted procedure up to 12 months post-implantation

Other outcomes

Locations

This trial has no locations.

Sponsors and contacts

Click on the lead sponsor to view all of their trials.

This trial is not recruiting at the moment. You can still explore other options: