About this trial
This study aims to compare two positions used for whole-breast radiation therapy in Thai women who have undergone breast-conserving surgery: lying on the back (supine) and lying face down (prone).
Radiation therapy after breast-conserving surgery helps reduce the risk of breast cancer returning. However, some radiation may reach nearby organs, particularly the heart and lungs. The position used during treatment may affect how much radiation these organs receive.
In this study, 24 women will undergo radiation treatment planning CT scans in both the supine and prone positions. Researchers will create a radiation treatment plan for each position and compare how well the plans cover the breast while minimizing radiation exposure to the heart and lungs. Each participant will receive actual radiation treatment in only one of the two positions, selected based on treatment planning results and clinical suitability.
The study will also assess patient comfort, positioning accuracy, treatment setup time, and treatment-related side effects.
The findings may help identify which patients are more likely to benefit from prone positioning and support individualized breast radiation treatment planning in Thai women.
Eligibility criteria
This trial does not accept healthy volunteersQualifiers
Histologically confirmed breast carcinoma or ductal carcinoma in situ (DCIS)
Status post breast-conserving surgery
Planned adjuvant breast-only radiotherapy
No indication for regional nodal irradiation
Disqualifiers
Planned treatment using Deep Inspiration Breath Hold (DIBH)
Bilateral breast cancer
Previous radiotherapy to the ipsilateral breast
Unable to tolerate either the prone or supine position
Trial design
Single group
Treatments tested in this trial
Whole-Breast Radiotherapy Positioning
RadiationParticipants will undergo CT simulation in both supine and prone positions after breast-conserving surgery. Whole-breast radiotherapy plans will be generated for both positions using 3-dimensional conformal radiotherapy (3D-CRT). Target coverage and organ-at-risk dosimetric parameters will be compared between the two plans. The treatment position will be selected according to predefined target coverage and organ-at-risk criteria. Participants will receive actual radiotherapy in the selected position only. The prescribed whole-breast dose is 40 Gy in 15 fractions, with a simultaneous integrated boost to 48 Gy in selected patients.
Treatment groups
Trial outcomes
Primary outcomes
Mean Heart Dose in Supine Versus Prone Treatment Plans
Mean radiation dose to the heart, measured in Gray (Gy), will be obtained from the dose-volume histogram for both the supine and prone treatment plans within the same participant. The mean heart dose will be compared between the two positions while maintaining acceptable target coverage.
Mean Ipsilateral Lung Dose in Supine Versus Prone Treatment Plans
Radiation dose to the lung on the same side as the treated breast will be assessed from the dose-volume histogram for both supine and prone treatment plans. Dosimetric parameters will include mean ipsilateral lung dose, and will be compared within the same participant while maintaining acceptable target coverage.
Secondary outcomes
PTV_Eval V95 in Supine Versus Prone Treatment Plans
PTV\_Eval V95, defined as the percentage of PTV\_Eval receiving at least 95% of the prescribed dose, will be obtained from the dose-volume histogram for both the supine and prone treatment plans within the same participant. PTV\_Eval V95 will be compared between the two positions. The unit of measure is percentage (%).
Treatment time from initial setup to treatment completion
Time required for patient positioning and setup until treatment is completed will be recorded and compared between the supine and prone positions. Time will be reported in minutes.
translational X Positioning Accuracy
Positioning accuracy will be assessed using setup verification imaging. Residual setup errors in the translational X axis will be recorded and compared between treatment positions. Positioning Accuracy will be reported in millimeters (mm).
translational Y Positioning Accuracy
Positioning accuracy will be assessed using setup verification imaging. Residual setup errors in the translational Y axis will be recorded and compared between treatment positions. Positioning Accuracy will be reported in millimeters (mm).