Synthetic PET From CT Improves Precision Diagnosis and Treatment of Lung Cancer: a Prospective, Observational, Multicenter Study

Trial statusRecruiting
Trial phaseNot listed
Trial typeObservational
Biological sexAll
Age18-85
SponsorShanghai Pulmonary Hospital, Shanghai, China

About this trial

This study aims to synthesise PET data that preserves biological relevance and adds clinical value to the diagnosis and prognosis of lung cancer by establishing anatomical-to-metabolic mapping based on paired diagnostic CT and FDG-PET scans, thereby prospectively validating the clinical utility of the model.

Eligibility criteria

This trial does not accept healthy volunteers

Qualifiers

Patients with non-small cell lung cancer scheduled to undergo PET-CT and pathological examinations;

Voluntarily participate and sign an informed consent form;

Disqualifiers

History of other malignant tumours;

Image artefacts;

Without pathological diagnostic information;

Without paired CT and FDG-PET scan images.

Trial population

Patients with non-small cell lung cancer scheduled to undergo PET-CT and pathological examinations

Trial design

Design model

Cohort

Time perspective

Prospective

Treatments tested in this trial

  • PET-CT

    Diagnostic test

    A PET-CT scan is performed prior to initiating systemic treatment for the tumour.

Treatment groups

No treatment groups listed

Trial outcomes

Primary outcomes

1

Structural similarity

This is a core outcome measure evaluating the degree of resemblance between the structural characteristics of synthetic PET images and reference PET images. It reflects whether the synthetic PET retains the key structural information of the original image, which is a fundamental indicator for confirming the structural relevance of synthetic PET.

Time frame
2025.12.1-2026.12.1
2

Peak Signal-to-Noise Ratio (PSNR)

A commonly used objective evaluation index in image quality assessment, calculated based on the mean square error between the synthetic PET image and the reference image. It quantifies the ratio of the maximum possible signal value in the image to the noise power that affects image quality. Higher PSNR values indicate that the synthetic PET image has less noise interference and better consistency with the reference image in terms of signal characteristics, thereby reflecting better retention of structural information.

Time frame
2025.12.1-2026.12.1
3

Structural Similarity Index (SSIM)

An index designed to simulate human visual perception to evaluate image structural similarity, which comprehensively considers three aspects: brightness, contrast, and structural consistency between the synthetic PET image and the reference image. The value range is between 0 and 1; a value closer to 1 means that the synthetic PET image has a higher degree of structural consistency with the reference image, indicating that the structural relevance is well retained.

Time frame
2025.12.1-2026.12.1
4

Metabolic Parameter Consistency

A key outcome measure for verifying the biological relevance of synthetic PET, which evaluates whether the metabolic characteristic parameters derived from synthetic PET are consistent with those from reference PET. Metabolic parameters are directly related to the biological functions of tissues/organs, so their consistency is crucial to ensuring that synthetic PET can be used for accurate biological activity assessment.

Time frame
2025.12.1-2026.12.1

Secondary outcomes

1

predictive performance

Validation study of indicators demonstrating the added value of synthetic PET in lung cancer diagnosis: Accuracy in distinguishing benign from malignant lesions, Accuracy in diagnosing lymph node metastasis, Accuracy in diagnosing distant metastasis, Including corresponding diagnostic sensitivity, specificity, positive predictive value, negative predictive value, area under the curve (AUC), etc.

Time frame
2025.12.1-2026.12.1

Other outcomes

Sponsors and contacts