About this trial
Pulse oximeters estimate arterial oxyhaemoglobin saturation (SaO₂) from photoplethysmographic signals recorded at peripheral sites (usually the fingertip), thus measuring the peripheral oxygen saturation (SpO₂). They are ubiquitous in emergency medicine because they offer a non-invasive, continuous measure of oxygenation and can alert clinicians to impending hypoxaemia, both during procedures such as rapid sequence intubation or sedation, or for continuous monitoring of patients. However, the accuracy of SpO₂ is often assumed to be instantaneous. This assumption is particularly hazardous during critical events involving rapid desaturation and resaturation. In such situations clinicians use SpO₂ readings to decide when to stop an apnea period during laryngoscopy and commence reoxygenation. If there is a delay between actual arterial desaturation and the displayed SpO₂, the clinician may not recognise hypoxaemia in time or may resume ventilation too late.
Eligibility criteria
This trial accepts healthy volunteersQualifiers
Healthy adult volunteers aged 18 to 60 years
Able to perform voluntary apnea for at least 30 seconds
Written informed consent, read and signed by the participant
Disqualifiers
History of chronic respiratory, cardiac, or hematological disease
Recent respiratory infection (< 2 weeks)
Use of vasoactive medications (e.g., beta-blockers, vasodilators)
Known or suspected pregnancy
Trial design
Single group
Treatments tested in this trial
Voluntary Apnea
Diagnostic testTwo pulse oximetry sensors (finger and earlobe) will be simultaneously applied, and baseline oxygen saturation (SpO₂), heart rate, and perfusion index will be recorded. The participant will then perform two voluntary apnea tests, during which these parameters will be continuously monitored to assess the timing of apnea, desaturation, nadir, and resaturation.
Treatment groups
Trial outcomes
Primary outcomes
Evaluation of SpO₂ Resaturation Following Voluntary Apnea
To characterize the temporal behavior of a modern finger pulse oximeter during voluntary apnea in healthy volunteers, with a particular focus on the delay (in seconds) between physiological reoxygenation and displayed SpO₂ (Time interval in seconds between the first breath following apnea and the first increase in SpO2.)
Secondary outcomes
Comparison of SpO₂ Temporal Parameters Between Finger and Ear Sensors
Saturation sensors will be placed on the ears and fingers of healthy volunteers. Saturation parameters will be recorded from both sensors and compared with the SpO2 saturation level (baseline SpO2): * Time (in seconds) between the onset of apnea and a decrease of ≥ 2% from baseline SpO2 * Time (in seconds) between the onset of apnea and the lowest SpO2 observed before the start of resaturation * Variable describing whether the SpO2 nadir (the lowest value) occurs before or after the resumption of ventilation
Quantification of SpO₂ Measurement Delay Between Measurement Sites
To quantify the magnitude of the SpO₂ measurement delay (in seconds) between the two measurement sites during the reoxygenation phase.
Assessment of Intra-Individual Measurement Variability
To assess intra-individual variability in key measurements (focus on the delay in seconds between physiological reoxygenation and displayed SpO2) across repeated apnea tests (2 different apnea)
Evolution of the Perfusion Index (PI) during Apnea and Reoxygenation by finger/auricular pulse oximeter
To describe changes in the perfusion index (PI in %) during apnea and reoxygenation. Baseline PI (%) will be recorded at finger and auricular sites in healthy volunteers over time in seconds. Minimum PI during apnea, magnitude of PI change during apnea, PI recovery time (in seconds) after rebreathing.