Temporary Aortic Compression With the Abdominal Tourniquet for Refractory Postpartum Hemorrhage

Trial statusRecruiting
Trial phaseNot applicable
Trial typeInterventional
Biological sexFemale
Age18-50
SponsorLLC UkrMedGroup

About this trial

This multicenter study aims to evaluate effectiveness and safety of using the AAJT-S device as a temporary intervention for severe, atony-related PPH that is refractory to standard therapies

Eligibility criteria

This trial does not accept healthy volunteers

Qualifiers

Age ≥18 years

Clinical diagnosis of postpartum hemorrhage (PPH) refractory to uterotonics and intrauterine balloon tamponade

Estimated blood loss greater than 1300 mL

Oral informed consent provided prior to device application

Disqualifiers

Patients with postpartum bleeding as a result of trauma, retained placenta or coagulopathy were excluded

Trial design

Design model

Single group

Treatments tested in this trial

  • Abdominal Aortic and Junctional Tourniquet - Stabilized (AAJT-S)

    Device

    The AAJT-S is a non-invasive, externally applied medical device designed to achieve temporary occlusion of the abdominal aorta and inferior vena cava by inflating a pneumatic bladder to 250 mmHg. In this study, the device will be used as a temporizing measure for patients with severe postpartum hemorrhage unresponsive to standard uterotonics and balloon tamponade. The device will be applied horizontally over the upper abdomen and inflated using a built-in pressure gauge. The intended effect is to reduce pelvic blood flow and allow time for mobilization of surgical resources and blood transfusion. Maximum application time will not exceed 60 minutes, in accordance with established safety guidelines.

Treatment groups

20 Participants
are divided into 1 treatment group
Group A: Participant Group/ArmExperimental treatment 1 intervention

Trial outcomes

Primary outcomes

1

Efficacy: The proportion of cases achieving rapid hemorrhage control after AAJT-S application.

Visible cessation of external vaginal bleeding (no ongoing blood flow from the cervix or vaginal canal observed by the clinical team) within 5 minutes of device inflation. The attending obstetrician will visually assess bleeding immediately after inflation and every 30 seconds until 5 minutes. "Control" will be recorded at the first time point when no active bleeding is observed (slight spotting is not considered ongoing hemorrhage). If bleeding persists beyond 5 minutes, the case is classified as "failure of primary endpoint," even if subsequent control is achieved.

Time frame
Within 5 minutes of AAJT-S device application
2

Safety: Incidence (i.e., Rate or Number of Participants), Severity and Seriousness of Device-related Adverse Events from placement until 6-week postpartum follow-up

Any untoward medical occurrence temporally associated with the AAJT-S device, regardless of causality

Time frame
From device application until 6-week postpartum follow-up

Secondary outcomes

1

Visually estimated blood loss (EBL)

Visually estimated blood loss (EBL) from delivery until AAJT-S placement (mL).

Time frame
From delivery until AAJT-S placement

Other outcomes

Sponsors and contacts