TES HT100 Clinical Validation for Brain Injury Screening in Patients With Mild Head Trauma or Neurological Symptoms

Trial statusRecruiting
Trial phaseNot applicable
Trial typeInterventional
Biological sexAll
Age18+
SponsorB&B srl

About this trial

The goal of this clinical study is to evaluate how accurately and safely the TES HT100 device can identify intracranial abnormalities in adult emergency department patients with mild head trauma or neurological symptoms that are not related to trauma and are not immediately life-threatening. The main questions it aims to answer are:

* How well does TES HT100 identify patients with intracranial abnormalities compared with head CT, the reference standard? * Is TES HT100 safe to use in this patient population? * Could TES HT100 help improve patient triage and use of hospital resources in the emergency setting?

Researchers will compare the result of TES HT100 with the head CT report.

Participants will:

* Be enrolled if they are adults presenting to the emergency department with mild head trauma or selected neurological symptoms * Undergo standard clinical assessment and head CT according to usual care * Have an additional TES HT100 examination lasting about 5 minutes, performed by trained personnel * Be assessed for device performance and any adverse events related to use of the device

Eligibility criteria

This trial does not accept healthy volunteers

Qualifiers

Age greater than 18 years

Provision of informed consent

Presentation to the Emergency Department with mild head injury, or

syncope

Disqualifiers

Age less than 18 years

Pregnant women

Metal plates or metal prostheses installed in the skull cap

Severe head trauma and/or extensive lacerated-contused areas

Trial design

Design model

Single group

Treatments tested in this trial

  • Temnographic Brain Screening Examination

    Diagnostic test

    A non-invasive, add-on diagnostic examination performed with the TES HT100 device to assess the presence or absence of intracranial abnormality in adult emergency department patients. The device uses ultra-low-power, non-ionizing electromagnetic waves in the 500-6500 MHz range and provides a binary on/off result. The examination lasts about 5 minutes, does not require direct contact with the patient's head, and is performed by trained personnel in addition to standard clinical evaluation and head CT.

Treatment groups

850 Participants
are divided into 1 treatment group
Group A: TES HT100 ExaminationExperimental treatment 1 intervention

Trial outcomes

Primary outcomes

1

Diagnostic accuracy of TES HT100 for detection of intracranial abnormalities

Diagnostic performance of TES HT100 compared with the head CT report as the reference standard, assessed by ROC-AUC and by sensitivity and specificity for identification of intracranial abnormalities.

Time frame
At the index emergency department visit, with TES HT100 performed within 24 hours before or after head CT
2

Rate of device-related adverse events

Incidence and type of adverse events related to the use of TES HT100 during the study.

Time frame
From TES HT100 examination through study participation completion, an average of 1 year

Secondary outcomes

1

Operator time associated with TES HT100-supported screening

Descriptive evaluation of operator time associated with use of TES HT100 during emergency department screening, based on the number of TES HT100 examinations performed per participant and the approximate duration of each examination (about 5 minutes), as described in the protocol.

Time frame
Day 1
2

Procedures associated with TES HT100-supported screening

Descriptive evaluation of workflow-related procedures associated with use of TES HT100 during emergency department screening, as part of the exploratory assessment of potential clinical benefit described in the protocol. This may include patient handling or organizational procedures required during the diagnostic pathway, such as patient transfer to a different bed or room or need for additional staff support.

Time frame
Day 1
3

Costs associated with TES HT100-supported screening

Descriptive evaluation of resource use and related cost considerations associated with use of TES HT100 during emergency department screening, as part of the exploratory assessment of potential clinical benefit described in the protocol.

Time frame
Day 1
4

Diagnostic performance of TES HT100 in predefined patient subgroups

Analysis of TES HT100 diagnostic performance, based on sensitivity and specificity versus head CT, in predefined subgroups, including younger patients, older patients, patients with or without prior injury or brain surgery, and patients with or without neurodegenerative disease.

Time frame
At the index emergency department visit, with TES HT100 performed within 24 hours before or after head CT

Other outcomes

Sponsors and contacts

Click on the lead sponsor to view all of their trials.