About this trial
The goal of this clinical study is to compare the tissue adequacy, cellularity, blood contamination, accuracy, sensitivity, specificity of the 22G Franseen needle combined with three different suction techniques (dry-suction, wet-suction, and slow-pull) in Endoscopic ultrasound-guided fine-needle biopsy for solid pancreatic lesions.
Eligibility criteria
This trial does not accept healthy volunteersQualifiers
None
Disqualifiers
contraindications to endoscopy, such as severe cardiovascular and cerebrovascular diseases;
bleeding coagulation dysfunction (prothrombin international normalized ratio ≥1.5, platelet count ≤ 50 000) or use of antiplatelet drugs;
confirmed pregnancy or possible pregnancy;
pathological diagnosis has been obtained by other methods;
Trial design
Crossover
Treatments tested in this trial
ABC
Procedure/SurgerySuction sampling should be conducted in the sequence of dry-suction, slow-pull and wet-suction.
ACB
Procedure/SurgerySuction sampling should be conducted in the sequence of dry-suction, wet-suction and slow-pull.
BAC
Procedure/SurgerySuction sampling should be conducted in the sequence of slow-pull, dry-suction and wet-suction.
BCA
Procedure/SurgerySuction sampling should be conducted in the sequence of slow-pull, wet-suction and dry-suction.
CAB
Procedure/SurgerySuction sampling should be conducted in the sequence of wet-suction, dry-suction and slow-pull.
CBA
Procedure/SurgerySuction sampling should be conducted in the sequence of wet-suction, slow-pull and dry-suction.
Treatment groups
6
Treatment groupsSee each treatment group below.
Trial outcomes
Primary outcomes
Tissue adequacy
Grade A, existing core tissue (defined as structurally intact tissue with a long axis length of at least 550 μm) that clearly characterizes the lesion and is sufficient for diagnosis; Grade B, the presence of core fragments that do not meet the histological criteria for structural integrity, but can still be diagnosed based on cell morphology; Grade C, no diseased tissue is found and no diagnosis can be made based on the sample.
Secondary outcomes
Cellularity
Grade A: Satisfactory, with more than 4 clusters, each containing at least 10 cells for cytological analysis; Grade B: Adequate, with 2-4 clusters, each containing at least 10 cells for cytological analysis; Grade C: Insufficient, with\<2 clusters suitable for cytological analysis or non-representative samples, or\<50 cells with clear nuclear structures.
Blood contamination
The histological blood contamination score is assessed by grading the percentage of red blood cells in the entire 40x magnified field of view. Grade A: Red blood cells are present in\<25%of the slides; Grade B: Red blood cells occupy 25%-50%of the slide; Grade C: Red blood cells are present in\>50%of the slides; Grade D: No tissue.
Diagnostic accuracy
Diagnostic accuracy was calculated as the proportion of true positive and true negative in all evaluated cases.
Diagnostic sensitivity
Diagnostic sensitivity was calculated as the proportion of true positives in patient cases.