The Effect of Speaking Valve on Physiological Parameters With Wearable Devices

Trial statusNot yet recruiting
Trial phaseNot listed
Trial typeObservational
Biological sexAll
Age18-90
SponsorJingyi Ge

About this trial

To explore the effect of speaking valves on physiological parameters of tracheostomized patients with wearable devices.

Eligibility criteria

This trial does not accept healthy volunteers

Qualifiers

Patient is not receiving mechanical ventilation.

Tolerates cuff deflation.

Upper airway patency is good, TTP < 10 cmH2O.

Hemodynamically stable, no organ failure, and no sepsis, Pulmonary infection is controlled.

Disqualifiers

Cannot tolerate deflation balloon.

Severe upper airway obstruction

Unstable vital signs.

Thick secretions, compromised airway protection.

Trial population

Population:Tracheostomy patients in a rehabilitation hospital undergoing pre-decannulation rehabilitation

Trial design

Design model

Cohort

Time perspective

Prospective

Treatments tested in this trial

Not listed

Trial groups

120 Participants
are grouped into 2 trial groups
Group A: Tolerance Cohort
Group B: Intolerance Cohort

Trial outcomes

Primary outcomes

1

Comparison of differences in key physiological parameters between two patient groups

Primary endpoint: Whether the tracheostomy patient's first use of a speaking valve is successful,duration of use 30 minutes.Primary Objectives:Data from 120 patients were collected using wearable devices,including respiratory rate(RR),heart rate(HR),fingertip blood oxygen saturation(SaO₂),respiratory movement amplitude(RMA),etc.RR and HR refer to the average respiratory and heart rates per minute during monitoring,respectively(breaths/min,beats/min).SaO₂ represents the average oxygen saturation recorded during monitoring(%).RMA means the average thoracic respiratory movement amplitude during monitoring(mm).This study aims to identify factors that can predict successful tolerance of the speaking valve, enhance the decannulation process focused on the "speaking valve," and increase the the success rate of decannulation.

Time frame
Specified assessment window:From 1 hour before initiation of speaking valve use to 1 hour after speaking valve removal (wearable devices monitoring period).

Secondary outcomes

Other outcomes

Sponsors and contacts

Click on the lead sponsor to view all of their trials.

Jingyi Ge

Lead sponsor

Capital Medical University

Sponsor institution

Beijing Rehabilitation Hospital

Collaborator

Peking University Cancer Hospital & Institute

Collaborator

Chinese PLA General Hospital

Collaborator

This trial is not recruiting at the moment. You can still explore other options: