About this trial
This randomized controlled trial aims to evaluate the effectiveness of high-intensity laser therapy (HILT) as an adjunct to conventional rehabilitation in patients undergoing arthroscopic rotator cuff repair.
Despite surgical repair, patients frequently experience postoperative pain, limited range of motion, and delayed functional recovery. Conventional physiotherapy represents the standard of care; however, additional strategies may be needed to optimize outcomes. High-intensity laser therapy has been proposed as a non-invasive intervention with potential analgesic and anti-inflammatory effects, but its effectiveness in the postoperative setting remains unclear.
Participants will be randomly allocated to one of two groups: an experimental group receiving HILT in addition to conventional physiotherapy, and a control group receiving sham laser therapy combined with the same rehabilitation program. Both groups will undergo standardized rehabilitation sessions including therapeutic exercise.
The primary outcome is pain intensity, measured using the Visual Analog Scale. Secondary outcomes include shoulder range of motion (active and passive), muscle strength, functional status assessed with the Constant-Murley Score, and patient-reported disability and quality of life measured using the Shoulder Pain and Disability Index and the Quick Disabilities of the Arm, Shoulder and Hand.
Assessments will be conducted at baseline (at the start of rehabilitation), during the intervention period after the fourth (T1), seventh (T2), and tenth (T3) physiotherapy sessions, and at follow-up at 4 months.
Eligibility criteria
This trial does not accept healthy volunteersQualifiers
Arthroscopic rotator cuff repair of one shoulder for partial or full-thickness tear
Willingness to provide written informed consent
Age between 30 and 70 years
Pain intensity greater than 40/100 on the Visual Analog Scale
Disqualifiers
Psychiatric disorders
Cognitive impairment
Rheumatic diseases or Fibromyalgia
Vascular diseases
Trial design
Parallel
Treatments tested in this trial
High intensity laser therapy
DeviceHigh-intensity laser therapy (HILT) will be administered using the HIRO TT device (ASA s.r.l., Italy), based on a solid-state Nd:YAG laser source with near-infrared emission at a wavelength of 1064 nm. The treatment protocol consists of 10 sessions delivered on alternate days. Each session will last 60 minutes and will include 15 minutes of laser therapy followed by 45 minutes of conventional physiotherapy. Laser therapy will be applied to two areas of 10 × 10 cm each, located at the anterolateral and posterior aspects of the shoulder. The treatment will be delivered using a pulsed emission with a frequency of 15 Hz, a total energy of 1000 J, and an energy density of 5 J/cm². The mean power will range between 6 and 10.5 W, with a peak power between 1 and 3 kW, for a total application time of 8 minutes and 30 seconds.
Sham laser therapy
Other interventionThe sham laser intervention will be delivered using the same HIRO TT device and identical treatment procedures as the active HILT group. The same anatomical areas (two treatment areas of 10 × 10 cm located at the anterolateral and posterior aspects of the shoulder) will be targeted, with identical session duration and patient positioning. During sham treatment, the device will remain switched on; however, no therapeutic laser emission will be delivered. This approach is intended to ensure participant blinding by replicating the visual and procedural aspects of the active intervention without providing any active therapeutic effect.
Treatment groups
Trial outcomes
Primary outcomes
Visual Analogue Scale
The VAS consists of a 100-mm horizontal line anchored by two descriptors: "no pain" (0 mm) and "worst imaginable pain" (100 mm). Participants will be asked to mark a point on the line corresponding to their perceived level of pain. The score will be determined by measuring the distance in millimeters from the left end of the line to the patient's mark, with higher scores indicating greater pain intensity.
Secondary outcomes
Visual Analogue Scale
The VAS consists of a 100-mm horizontal line anchored by two descriptors: "no pain" (0 mm) and "worst imaginable pain" (100 mm). Participants will be asked to mark a point on the line corresponding to their perceived level of pain. The score will be determined by measuring the distance in millimeters from the left end of the line to the patient's mark, with higher scores indicating greater pain intensity.
Passive Range of Motion
Passive shoulder range of motion (ROM) will be assessed using a digital goniometer following standardized measurement procedures. Movements evaluated will include shoulder flexion, abduction, internal rotation and external rotation at 90° of abduction, and external rotation at 0° of abduction. Measurements will be performed with the patient in the supine position. For each movement, three repetitions will be recorded and the mean value will be used for analysis. Results will be expressed in degrees.
Active Range of Motion
Active shoulder range of motion (ROM) will be assessed using a digital goniometer following standardized measurement procedures. Movements evaluated will include shoulder flexion, abduction, and external rotation at 0° of abduction. Measurements will be performed with the patient in a standing position. For each movement, three repetitions will be recorded and the mean value will be used for analysis. Results will be expressed in degrees.
Muscle strength: Handheld dynamometer
Shoulder muscle strength will be assessed using a handheld digital dynamometer following standardized and reproducible testing positions. Isometric strength will be measured for shoulder abduction, internal rotation, and external rotation. Internal and external rotation will be evaluated with the patient in a seated position, with the arm at 0° and 90° of abduction in the scapular plane. Shoulder abduction will be assessed with the arm positioned at 45° of abduction. For each movement, three maximal isometric contractions of 5 seconds will be performed, with 30 seconds of rest between trials. The highest value recorded will be used for analysis. Results will be expressed in kilograms.
Sponsors and contacts
Click on the lead sponsor to view all of their trials.
This trial is not recruiting at the moment. You can still explore other options: